Oil-Free Vaccum Pump Combination Pump (1-Cylinder Spec) Both vacuum and blower capability from a single pump.

Built to Order Item

KCP100D-VB1-01A
KCP100D-VB2-01A/KCP150D-VB-01A

  • -VB1:Aftercooler Included
  • -VB2:Aftercooler Not Included
Degree of Vacuum
0 to 60 kPa or higher
Pressure
0 to 70 kPa or higher
Motor Output
5.5kW
Flow Rate
0 to 192 m3/h
  • Suitable for printing machinery, bookbinding, bag manufacturing machinery, etc.
  • Reliable, Made-in-Japan Pump
  • 20,000 Hour Long Life
KCP100D
KCP100D-VB
KCP150D
KCP150D-VB
  • Rotor
    Rotor
  • Noise Reduction
    Noise Reduction
  • Inverter
    Inverter
  • Long Life
    Long Life
  • Dry Slide
    Dry Slide
  • Easy Operation
    Easy Operation
Choosing the aftercooler spec. Greatly reduces the exhaust temperature.

The aftercooler equipped KCP100D-VB1-01A can exceed exhaust temperatures of 45 ℃.

Aftercooler
Exhaust Air is Clean Air
  • Zero Abrasive Particulate
    Vaneless means clean air with zero abrasive particulate.
  • Zero Oil
    The pump room is completely dry. Zero-Oil Clean Air.

Specifications

Aftercooler Included Aftercooler Not Included
KCP100D-VB1-01A KCP100D-VB2-01A
Motor Output kW 5.5
Flow Rate (50/60 Hz) ※1 m3/h Vacuum: 97/118; Blower: 97/118
m3/min Vacuum: 1.6/2.0; Blower: 1.6/2.0
Continuous Operating Vaccum ※2 kPa 60 or less
Continuous Pressure ※3 kPa 70 or less
Exhaust Tempreture ※4 45 or less 125 or less
Operating Noise Level ※5 dB 87
Piping Connection Size   Intake side: Rc 1 1/4, Exhaust: Rc 1 1/4
Mass kg 163 142
Motor Rated Voltage and frequency※6   Three-phase 200 V @ 50/60 Hz, 220 V @ 60 Hz
Output, Number of Units   5.5 kW / 2P × 1 Unit
Specifications   Top Runner compliant, high efficiency motors
Working Environment Place of Installation   Indoors
Allowable Ambient Temperature※7 0 to 40
Allowable Ambient Humidity   65 ±20%RH(JIS Z8703)
Operable Elevation ※8 m 1000 or lower
Accessory (Sold Separately)   Vacuum controller, Hour meter, pressure controller, compound gauge
  1. This is the designed flow rate based on the cylinder volume of the pump. Confirm the actual flow rate based on the pressure-flow diagram.
  2. Upper limit of the sustainable degree of vacuum of the pump. Pressures indicated are when operating the pump under 1 atm. When operating at atmospheric pressure in areas of high elevation, there will be a difference in the actual degree of vacuum compared to operating at atmospheric pressure at sea level. Accordingly, the actual ultimate vacuum will be lower than the noted value. Simplified Correction Formula for Ultimate Vacuum [kPa] = Written Operating Value (from the specifications chart) [kPa] - Elevation [m] < 0.0115 [kPa/m]
  3. Upper limit of continuous operable exhaust pressure. Do not operate the pump above this limit. Doing so can reduce the lifespan of the pump and may result in breakdown or an accident.
  4. The indicated temperature is the rise in temperature over the ambient temperature.
  5. Noted operating noise level is when using an ORION motor.
  6. The power supply voltage must not have intermittent fluctuations greater than 10%, or 5% if fluctuations are continued.
  7. If the pump is started where the ambient temperature is around 0 °℃, a high frequency noise may be heard. The noise will naturally go away in a short time and does not indicate abnormal operation. If a high pitch noise continues for more than 30 minutes, consult with your dealer or a qualified repair person.
  8. Please consult with ORION if the product is to be operated at an elevation above 1000 m.
KCP150D-VB-01A
Motor Output kW 5.5
Flow Rate (50/60 Hz) ※1 m3/h 158/192
m3/min 2.6/3.2
Continuous Operating Vaccum ※2 kPa 0 - 60 (1 atm or lower)
Continuous Pressure ※3 kPa 0 to 60
Operating Noise Level ※4 dB 72/79
Piping Connection Size   Intake: Rp 1 1/2, Exhaust: R1 1/2
Mass kg 142
Motor Rated Voltage and frequency※5   Three-phase 200 V - 50/60 Hz, 220 V - 60 Hz
Output, Number of Units   5.5 kW / 2P × 1 Unit
Specifications   Top Runner compliant high efficiency motors
Working Environment Place of Installation   Indoors
Allowable Ambient Temperature※6 0 to 40
Allowable Ambient Humidity   65 ±20%RH(JIS Z8703)
Operable Elevation ※7 m 1000 or lower
Accessory (Sold Separately)   Intake filter / Vacuum controller / Pressure controller / Hour meter
Optional Equipment   Compound gauge
  1. This is the designed flow rate based on the cylinder volume of the pump. Confirm the actual flow rate based on the pressure-flow diagram.
  2. Under ambient pressure of 1 atm.
  3. Upper limit of continuous operable exhaust pressure.
  4. Values are actual measured values using the standard built-in ORION motor, operating at a degree of vacuum of 40 kPa and a pumping pressure of 20 kPa. These are not warranted values.
  5. The power supply voltage must not have intermittent fluctuations greater than 10%, or 5% if fluctuations are continued.
  6. If the pump is started where the ambient temperature is around 0 ℃, a high frequency noise may be heard. The noise will naturally go away in a short time and does not indicate abnormal operation. If a high pitch noise continues for more than 30 minutes, consult with your dealer or a qualified repair person.
  7. Please consult with ORION if the product is to be operated at an elevation above 1000 m.