KRF Heavy Duty Standard Model Dry PumpSafety Enhanced Design・Low Noise・Long Life・Environmentally Friendly

KRF70 / KRF110

Continuous Operating Vacuum
60 kPa or less (V/VB)
80 kPa or less (VH / VBH)
Continuous Operating Pressure
60 kPa or less (B/VB)
70 kPa or less (BH)
80 kPa or less (VBH)
Flow Rate
1350 to 2200 L/min (60 Hz)
  • Safe and Environmentally Conscious
    CE Marking Certified
    • Models without motors are excluded.
  • Quiet Operation
    Noise level reduced by 3 dB
    (compared with conventional models)
  • Long Life
    Increased 10% with newly developed vane blade material.
    (compared with conventional models)
KRF70
KRF70-V-01B

Specifications

Model KRF70- V-01B V-04B ※4 VH-01B VH-04B ※4
Designed Pumping Capacity(50/60 Hz) ※1 L/min 1130/1350
Ultimate Vacuum ※2 kPa (min.) 90
Continuous Operating Vacuum ※3 kPa (max.) 60 80
Continuous Operating Pressure ※3 kPa (max.) -
Piping Connection Size   Rc 1
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
Noise level (50/60 Hz) ※5 dB 67/68 73/74
Motor kW 2.2
Mass kg 94
Model KRF70- B-01B B-04B ※4 BH-01B BH-04B ※4
Designed Pumping Capacity(50/60 Hz) ※1 L/min 1130/1350
Ultimate Vacuum ※2 kPa (min.) -
Continuous Operating Vacuum ※3 kPa (max.) -
Continuous Operating Pressure ※3 kPa (max.) 60 70
Piping Connection Size   Rc 1
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
Noise level (50/60 Hz) ※5 dB 74/76
Motor kW 2.2
Mass kg 94
Model KRF70- VB-01A VB-04B ※4 VBH-01B VBH-04B ※4
Designed Pumping Capacity (50/60 Hz) ※1 L/min 1130/1350
Ultimate Vacuum ※2 kPa (min.) -
Continuous Operating Vacuum ※3 kPa (max.) 60 or less altogether 80 or less altogether
Continuous Operating Pressure ※3 kPa (max.)
Piping Connection Size   Rc 1
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 400/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
10.6/
10.0、9.6、9.6
5.3/
5.0、4.8、4.8
Noise Level (50/60 Hz) ※5 dB 67/68 73/74
Motor kW 2.2
Mass kg 94

Model KRF110- V-01B V-04B ※4 B-01B B-04B ※4
Designed Pumping Capacity (50/60 Hz) ※1 L/min 1850/2200
Ultimate Vacuum ※2 kPa (min.) 90 -
Continuous Operating Vacuum ※3 kPa (max.) 60 -
Continuous Operating Pressure ※3 kPa (max.) - 60
Piping Connection Size   Rc 1 1/4
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 16.6/
15.6、14.8、14.8
8.5、8.3、8.3/
7.8、7.4、7.4
16.6/
15.6、14.8、14.8
8.5、8.3、8.3/
7.8、7.4、7.4
Noise level (50/60 Hz) ※5 dB 74/75 76/77
Motor kW 3.7
Mass kg 131
Model KRF110- VB-01B VB-04B ※4
Designed Pumping Capacity (50/60 Hz) ※1 L/min 1850/2200
Ultimate Vacuum ※2 kPa (min.) -
Continuous Operating Vacuum ※3 kPa (max.) 60 or less altogether
Continuous Operating Pressure ※3 kPa (max.)
Piping Connection Size   Rc 1 1/4
Voltage (50/60 Hz) V 3-Phase 200/
3-Phase 200, 220, 230
3-Phase 380, 400, 415/
3-Phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 16.6/
15.6、14.8、14.8
8.5、8.3、8.3/
7.8、7.4、7.4
Noise level (50/60 Hz) ※5 dB 74/75
Motor kW 3.7
Mass kg 131
  1. Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.
  2. Operation not allowed at ultimate vacuum.For model selection purposes only.
  3. Operable range of vacuum (pressure).
  4. "04" models are special order items.
  5. Operating noise measured on a new pump with an ORION recommended motor running at the recommended vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
  • Operating environment (inlet air) conditions: air temp: 0 to 40 ℃, humidity: normal level (65±20%).
  • Allowable intermittent power supply voltage fluctuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
  • Please install an overload protection device (such as a thermal relay).
  • See specifications sheet for further details.
  • If detailed specifications are required, please Contact ORION to request a specifications sheet.

External Dimensions(Units:mm)

dimensions
dimensions

Performance Data