KHA High Vacuum Dry PumpContinuous operation at ultimate pressure (8 kPa or lower).
KHA100-301 / KHA200-301A
KHA400-301A / KHA750-301B
- Ultimate Pressure
- 8 kPa [abs] (max.)
- Flow Rate
- 65 to 400 L/min (60 Hz)
- Continued operation possible at ultimate pressure (8 kPa).
- High degree of vacuum, excellent substitune pump for electronic component and small parts handling automated equipment.
Specifications
Model KHA | 100-301-G1 | 200-301A-G1 | 400-301A-G1 | 750-301B-G1 | |
---|---|---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | 55/65 | 120/145 | 220/260 | 330/400 |
Ultimate Pressure ※2 | kPa [abs] (max.) | 8 | |||
Piping Connection Size | Rc 1/4 | Rc 3/8 | |||
Voltage (50/60 Hz) | V | 3-phase 200 / 3-phase 200, 220 | |||
Standard Motor Current Rating (50/60 Hz) | A | 0.69/0.6, 0.62 | 1.56/1.37, 1.36 | 2.29/2.08, 1.99 | 3.8/3.4, 3.4 |
Operating Noise Level (50/60 Hz) ※3 | dB | 60/61 | 61/62 | 63/66 | 67/70 |
Built-In Motor | kW | 0.1 | 0.2 | 0.4 | 0.75 |
Mass | kg | 11 | 13 | 21 | 38 |
- Designed Pumping Capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.
- Pump can be continuously operated at the maximum attainable vacuum.
- Operating noise level measured on a new pump with the standard built-in ORION motor. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
- Working vacuum range: 48 kPa [abs] to ultimate pressure.
- Maximum operational pressure variation pulse: 13.3 kPa [abs] /s.
- Models with ductable exhaust available (KHA100A・200A・400A・750A). When ducting off exhaust, the allowable back pressure from the piping is 25 kPa. (This pressure should not be used for any purpose.)
- Operating environment (inlet air) conditions: air temp: 0 to 40 °℃, humidity: normal levels (65±20%).
- Due to the high compression ratios found in high-compression pumps, condensation can easily form within the pump. Therefore the following measures should be taken in order to avoid trouble from rust due to condensation: During a trial run (operation of 5 minutes or less, such as a momentary operation or short test run) if the operating pressure goes above 48 kPa [abs], then a dry run of 10 to 15 minutes should be made at a pressure of 48 kPa [abs] at the vacuum side of the pump.
- Allowable intermittent power supply voltage fluctuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
- Please install an overload protection device (such as a thermal relay). Setting guideline (may vary depending on the specific application): For Three-phase motors, use the current rating listed on the motor nameplate as a guide.
- See specifications sheet for further details.
- If detailed specifications are required, please Contact ORION to request a specifications sheet.