Oil-Free Vaccum Pump KCM310 Degree of Vacuum: 100 kPa! 5.5kW Output Spec. Motor with Control Panel and Inverter in a Single Package

Built to Order Item

KCM310-V

  • -01 Models: Without Casters
  • -02 Models: Includes Casters
Degree of Vacuum
0 to 100 kPa or higher
Motor Output
5.5 kW
Flow Rate
0 to 308 m3/h
  • This inverter and multi-unit control combination offers improved energy saving performance.
  • 5.5kW Output Spec. Motor with Control Panel and Inverter in a Single Package.
KCM310
KCM310
eco speed control
[eco speed® control]
Energy saving mechanism that
automatically adapts motor speed to changes in air consumption.
  • 2-Stage Rotor
    2-Stage Rotor
  • Full-Range Vacuum
    Full-Range Vacuum
  • Modular Design
    Modular Design
  • Intelligent Touch Panel
    Intelligent Touch Panel
  • Centralized Vacuum System
    Centralized Vacuum System
  • IoT
    IoT
Continuous operation

Thanks to the 2-stages (2-stage compression), we can achieve continuous operation at the attainable pressure of 100 kPa, despite being oil-free.

Compact, space saving design

The compact modular design that doesn't require side maintenance space, making installation easy, anywhere.

Compact, Space Saving Design
Compact, Space Saving Design

▲ Setup possible with walls on both sides of the product.

LOOk Energy saving pump construction that covers the range from low to high degrees of vacuum. Patented
  • Electrical power consumption optimized over the full range of degree of vacuum (from open-atmosphere to attainable vacuum).
  • Constructed to prevent over-compression of exhaust air.

At high degrees of vacuum, a back-flow of air is formed in the exhaust process, and this returning air results in a loss of energy.
The KCM series sports a new design that reduces energy losses by reducing the volume just before opening the exhaust port.
On the other hand, when open, the volume of air increases, there is an over-increase in pressure, and power consumption will rise."Supplementary Exhaust Ports" are established and the power consumption drops.

Energy saving pump construction
Expansion Possible to Multi-Unit Control System

Expansion to a multi-unit control system is possible by using our Group Controller.

Multi-Unit Control System
Intelligent Touch Panel for Easy Operation

Various operating conditions and settings can be confirmed and operated, and operating conditions can be confirmed via the visual and intuitive touch panel.

インテリジェントタッチパネル
  1. ❶ Display Measured Degree of Vacuum
    Digital display of degree of vacuum (in 1 kPa units)
  2. ❷ Display Set Degree of Vacuum
    Digital for easy vacuum settings (in 1 kPa units)
  3. ❸ Display Operating Mode
  4. ❹ Display Operating Load
  5. ❺ Display Operating Conditions
  6. ❻ Operation Control Buttons
  7. ❼ Display Alarm Number
  8. ❽ Display Pump Start/Stop Time

Specifications

KCM310-V-01/02
Motor Output kW 5.5
Flow Rate ※1 m3/h 308
m3/min 5.1
Ultimate Vaccum ※2 kPa 100 or higher
kPa(abs) 1.3 or lower
Operating Noise Level ※3 dB 72
Piping Connection Size   Rc2
Mass kg 485(01)、495 (02)
Motor Rated Voltage And Frequency※4   Three-phase 200 V - 50/60 Hz,
220 V - 60 Hz
Output Number of Units   5.5 kW / 4P ・ 1 Unit
Specifications   Top Runner compliant high efficiency motor
Working Environment Place of Installation   Indoors
Allowable Amnient Temperaturer※5 5 to 40
Allowable Ambient Humidity   65 ±20%RH(JIS Z8703)
Operable Elevation ※6 m 1000 or lower
Control Method   Built-in load detecting automatic speed control circuit.
Automatic Speed Control Range Hz 20 to 60
  1. This is the designed flow rate based on the cylinder volume of the pump. Confirm the actual flow rate based on the pressure-flow diagram.
  2. Under ambient pressure of 1 atm. When operating at high elevations, there will be a difference in operating pressure from operation at a location under 1 atm of pressure. The calculation to measure the ultimate vacuum while operating at other elevations is as follows: Ultimate Vacuum Under Pressure (simplified) [kPa] = Specified Ultimate Degree of Vacuum [kPa] = Altitude [m] × 0.0115 [kPa/m]
  3. Operating noise measured at an operating vacuum of 80kPa with 200V / 60Hz power supply, and is not a guaranteed value.
  4. The power supply voltage must not have intermittent fluctuations greater than 10%, or 5% if fluctuations are continued.
  5. If the pump is started where the ambient temperature is around 5℃, a high frequency noise may be heard. The noise will naturally go away in a short time and does not indicate abnormal operation. If a high pitch noise continues for more than 30 minutes, consult with your dealer or a qualified repair person.
  6. Please consult with ORION if the product is to be operated at an elevation above 1,000 m.