Dry Vaccum Pump
KCE series (Claw type/Water Cooled)
Energy savings thanks to our industry-first inverter controlled vacuum pump.

KCE120F-VH-01 / KCE120F-VH-02
KCE190F-V-01 / KCE190F-VH-01
KCE190F-V-02 / KCE190F-VH-02
KCE310F-V-01 / KCE310F-VH-01
KCE310F-V-02 / KCE310F-VH-02
KCE380F-V-01 / KCE380F-VH-01
KCE380F-V-02 / KCE380F-VH-02
KCE620F-V-01 / KCE620F-VH-01
KCE620F-V-02 / KCE620F-VH-02

  • -01 Models: Without Casters
  • -02 Models: Includes Casters
  • -VH Models: High vaccum Models
Degree of Vacuum
0 to 94 kPa or higher
Motor Output
2.2 to 11kW
Flow Rate
0 to 616 m3/h
  • Introducing New Models with an Extended 30,000-hour Overhaul Cycle (KCE310F-V/VH,620F-V/VH)
  • All KCE-F Series models in the 120 to 620 range support "continuous attainable operation".
  • Improved scalability for centralized vacuum systems.
KCE Series
KCE Series
eco speed control
  • Rotor
    Rotor
  • Noise Reduction
    Noise Reduction
  • Inverter
    Inverter
  • Long Life
    Long Life
  • Dry Slide
    Dry Slide
  • Easy Operation
    Easy Operation
Our modularization offers improved installation and space savings.
Automatic Recognition of Vacuum Pump Load Conditions

The installation footprint is only 87% compared to our previous model.

footprint
Reduced-Noise Construction

Our new-concept low-noise bodies and contactless rotor are effective at providing a low-noise working environment that is easy on workers. Operating noise sounds as if it were cut in half.
※Compared with our contact-type vacuum pump.

lowーnoiseーstructure
Our intelligent touch panel and multi-information LED display make operation easier and improves visibility.

Easy operation and monitoring by simply touching various settings and operating conditions on the display. And the LED display shows the product operating condition at a glance.

Panel Details and Functions
  1. ❶ Display Measured Degree of Vacuum
    Digital display of degree of vacuum(in 1 kPa units)
  2. ❷ Display Set Degree of Vacuum
    Digital for easy vacuum settings(in 1 kPa units)
  3. ❸ Display Operating Mode
  4. ❹ Display Operating Load
  5. ❺ Display Operating Conditions
  6. ❻ Operation Control Buttons
  7. ❼ Display Alarm Number
  8. ❽ Display Pump Start/Stop Time
Intelligent LCD Panel
LED Display Function

Safety and protection devices in an all-in-one package.
LCD display shows not only error numbers but also the nature of the trouble.

Error Display Functions

Centralized Vacuum Systems

KCE-F series comes standard with terminals to connect to the Eco Multi-Box EMB10A-NC-01 (sold separately). Multi-unit control is possible by connecting to the EMB10A-NC-01.
If an increase is desired at a later time, expansion up to 10 pumps is possible with one EMB10-NC-01 unit.

Good for unforeseen situations!

A centralized vacuum system that keeps the vacuum line operating and maintains your factory operating rate even when unforeseen situations crop up.

EMB10-NC
If the control board malfunctions...

Even if the EMB10A-NC-01 fails due to some sort of trouble, individual vacuum pumps will continue to operate using the controllers built into the vacuum pumps.

If the inverter malfunctions...

If the inverter built into the vacuum pump goes down, continued operation is possible by automatically or manually switching to a commercial power supply. (Not applicable during pump failure.)

The combination of inverter control (eco speed control) and multi-unit control yields optimum operation and greater energy savings.

Optimum flow rate for lines that cannot run off simple ON/OFF control systems.
With the eco speed control and ORION's Multi-Unit Control System, we can optimally adapt to loads and maintain the optimum vacuum to meet the user's application.

Specifications

Standard Models
KCE190F-V-01 KCE310F-V-01 KCE380F-V-01 KCE620F-V-01
KCE190F-V-02 KCE310F-V-02 KCE380F-V-02 KCE620F-V-02
Motor Output kW 3.7 5.5 7.4 11
Flow Rate※1 m3/h 192 308 384 616
m3/min 3.2 5.1 6.4 10.3
Continuous Operating Vacuum※2 0 to 80
Ultimate vacuum※2 kPa 94 or higher
Operating Noise Level※3 dB 65 71 68 74
Piping Connection Size   Rc1 1/2 Rc2 Rc3
Mass※4 kg 333 495 521 706
Motor Rated Voltage And Fiequency※5   Three-phase 200V-50/60Hz 220V-60Hz
Output, Number of Units   3.7KW ・ 2P×1 unit 5.5kW ・ 2P×1 unit 3.7kW ・ 2P×2 units 5.5KW ・ 2P×2 units
Specifications   Top Runner compliant high efficiency motors.
Working
Environment
Place of Installation   Indoors
Allowable Ambient Temperature※6 5 to 40
Allowable Ambient Humidity   65 ± 20%RH(JIS Z8703)
Operable Elevation※7 m 1000 or lower
Control Method   Built-in load detecting automatic speed control circuit.
Automatic Speed Control Range Hz 20 to 60
Recommended Overhaul Cyde h 20000 30000 20000 30000
  1. This is the designed flow rate based on the finder volume of the pump. Confirm the actual flow rate based on the pressure-flow diagram.
  2. Under ambient pressure of 1 atm. When operating at high elevations, there will be a difference in operating pressure from operation at a location under 1 alm of pressure. The calculation to measure the ultimate vacuum while operating at other elevations is as follows: Ultimate Vacuum Under Pressure (Simplified) [kPa] = Specried Ultimate Degree of Vacuum [kPal] - Altitude [m] X 0.0115 [kPa/m].
  3. Operating noise measured at an operating vacuum of 80 kPa, and is not a quaranteed value.
  4. The specification includes casters and the mass including the casters will be the noted mass plus an aditional 5 kg KCE620F an additional 10 kg for KCE620F.
  5. The power supply voltage must not have intermittent fluctuations greater than 10%, or 5% i luctuations are continued.
  6. If the pump is started where the ambient temperature is around 0 °C, a high frequency noise may be heard. The noise will naturally go away in a short time and does not indicale abnoma operation. If a high pitch noise continues for more than 30 minutes, cousult with your dealer or a qualified repair person.
  7. Please consult with ORION if the product is to be operated at an elevation above 1000 m.
High Vacuum Models Model
KCE120F-VH-01 KCE190F-VH-01 KCE310F-VH-01
KCE120F-VH-02 KCE190F-VH-02 KCE310F-VH-02
Motor Output kW 2.2 3.7 5.5
Flow Rate※1 m3/h 117 192 308
m3/min 1.95 3.2 5.1
Continuous Operating Vacuum※2 kPa 0 to Ultimate vacuum 60 to Ultimate vacuum
Ultimate vacuum※2 kPa 94 or higher
Operating Noise Level※3 dB 65 67 71
Piping Connection Size   Rc1 1/2 Rc2
Mass※4 kg 310 333 498
Motor Rated Voltage And Fiequency※5   Three-phase 200V-50/60Hz 220V-60Hz
Output, Number of Units   2.2KW ・ 2P×1 unit 3.7KW ・ 2P×1 unit 5.5KW ・ 2P×1 unit
Specifications   Top Runner compliant high efficiency motors.
Working
Environment
Place of Installation   Indoors
Allowable Ambient Temperature※6 5 to 40
Allowable Ambient Humidity   65 ± 20%RH(JIS Z8703)
Operable Elevation※7 m 1000 or lower
Control Method   Built-in load detecting automatic speed control circuit.
Automatic Speed Control Range Hz 20 to 60
Recommended Overhaul Cyde h 20000 20000 30000
High Vacuum Models Model
KCE380F-VH-01 KCE620F-VH-01
KCE380F-VH-02 KCE620F-VH-02
Motor Output kW 7.4 11
Flow Rate※1 m3/h 384 616
m3/min 6.4 10.3
Continuous Operating Vacuum※2 kPa 60 to Ultimate vacuum
Ultimate vacuum※2 kPa 94 or higher
Operating Noise Level※3 dB 73 74
Piping Connection Size   Rc2 Rc3
Mass※4 kg 521 706
Motor Rated Voltage And Fiequency※5   Three-phase 200V-50/60Hz 220V-60Hz
Output, Number of Units   3.7KW ・ 2P×2 units 5.5KW ・ 2P×2 units
Specifications   Top Runner compliant high efficiency motors.
Working
Environment
Place of Installation   Indoors
Allowable Ambient Temperature※6 5 to 40
Allowable Ambient Humidity   65 ± 20%RH(JIS Z8703)
Operable Elevation※7 m 1000 or lower
Control Method   Built-in load detecting automatic speed control circuit.
Automatic Speed Control Range Hz 20 to 60
Recommended Overhaul Cyde h 20000 30000
  1. This is the designed flow rate based on the finder volume of the pump. Confirm the actual flow rate based on the pressure-flow diagram.
  2. Under ambient pressure of 1 atm. When operating at high elevations, there will be a difference in operating pressure from operation at a location under 1 alm of pressure. The calculation to measure the ultimate vacuum while operating at other elevations is as follows: Ultimate Vacuum Under Pressure (Simplified) [kPa] = Specried Ultimate Degree of Vacuum [kPal] - Altitude [m] X 0.0115 [kPa/m].
  3. Operating noise measured at an operating vacuum of 80 kPa, and is not a quaranteed value.
  4. The specification includes casters and the mass including the casters will be the noted mass plus an aditional 5 kg KCE620F an additional 10 kg for KCE620F.
  5. The power supply voltage must not have intermittent fluctuations greater than 10%, or 5% i luctuations are continued.
  6. If the pump is started where the ambient temperature is around 0 °C, a high frequency noise may be heard. The noise will naturally go away in a short time and does not indicale abnoma operation. If a high pitch noise continues for more than 30 minutes, cousult with your dealer or a qualified repair person.
  7. Please consult with ORION if the product is to be operated at an elevation above 1000 m.

External Dimensions(units:mm)

Standard Models
外形図
High Vacuum Models Model
外形図

Performance Data

  • Do not operate at the conditions indicated by the dashed pressure and flow rate lines.
    Operating condition: 20℃.
  • Typical value for standard built-in motor and not a guaranteed value.
Standard Models
performance
High Vacuum Models Model
performance