CBX Combination Dry Pump2-cylinder, Dual Function Compact and Lightweight Pump

CBX62/CBX62-A

Continuous Operating Vacuum
60 kPa or less
(CBX62-A-01B not inclided)
Continuous Operating Pressure
60 kPa or less
(CBX62-A-01B not inclided)
Flow Rate
1115 L/min (60 Hz)
  • 2-cylinder (vacuum and pressure) design allows simultaneous vacuum and pressure operation for individual vacuum and pump pressures below 60 kPa.
  • Compared with exsting Orion models, the CBX line offers smaller size and lighter weight in an easy to use package.
CBX
CBX62-01B-G1

Specifications

Model CBX62- 01B-G1 (V,B Specifications) A-01B-G1 (VB,VB Specifications)
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1: 935/1115
Pump 2: 935/1115
Pump 1: 935/1115
Pump 2: 935/1115
Continuous Operating Vacuum ※2 kPa (max.) 60 55/35 ※4
Continuous Operating Pressure ※2 kPa (max.) 60 20/50 ※4
Piping Connection Size   Rc 1
Motor Voltage (50/60 Hz) V 3-phase 200 / 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 15.4/14.4, 13.6, 13.6
Operating Noise Level (50/60 Hz) ※3 dB 78/79 -
Built-In Motor kW 3.7
Mass kg 112
  1. Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.
  2. Operable range of vacuum (pressure).
  3. Operating noise measured on a new pump with an ORION recommended motor running at normal vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
  4. Maximum combined output per cylinder (max. vacuum/max. pressure): Pump 1: (55 or lower / 20 or lower), Pump 2: (35 or lower / 50 or lower.)
  • Operating environment (inlet air) conditions: air temp: 0 to 40℃, humidity: normal levels (65±20%).
  • Allowable intermittent powersupply voltage flucuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
  • Please install an overload protection device (such as a thermal relay).
  • If detailed specifications are required, please Contact ORION to request a specifications sheet.

External Dimensions(units:mm)

dimensions

Performance Date

Vacuum
performance
Blower
performance