CBX Combination Dry Pump2-cylinder, Dual Function Compact and Lightweight Pump
CBX62/CBX62-A
- Continuous Operating Vacuum
- 60 kPa or less
(CBX62-A-01B not inclided)
- Continuous Operating Pressure
- 60 kPa or less
(CBX62-A-01B not inclided)
- Flow Rate
- 1115 L/min (60 Hz)
- 2-cylinder (vacuum and pressure) design allows simultaneous vacuum and pressure operation for individual vacuum and pump pressures below 60 kPa.
- Compared with exsting Orion models, the CBX line offers smaller size and lighter weight in an easy to use package.
Specifications
Model CBX62- | 01B-G1 (V,B Specifications) | A-01B-G1 (VB,VB Specifications) | |
---|---|---|---|
Designed Pumping Capacity (50/60 Hz) ※1 | L/min | Pump 1: 935/1115 Pump 2: 935/1115 |
Pump 1: 935/1115 Pump 2: 935/1115 |
Continuous Operating Vacuum ※2 | kPa (max.) | 60 | 55/35 ※4 |
Continuous Operating Pressure ※2 | kPa (max.) | 60 | 20/50 ※4 |
Piping Connection Size | Rc 1 | ||
Motor Voltage (50/60 Hz) | V | 3-phase 200 / 3-phase 200, 220, 230 | |
Standard Motor Current Rating (50/60 Hz) | A | 15.4/14.4, 13.6, 13.6 | |
Operating Noise Level (50/60 Hz) ※3 | dB | 78/79 | - |
Built-In Motor | kW | 3.7 | |
Mass | kg | 112 |
- Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.
- Operable range of vacuum (pressure).
- Operating noise measured on a new pump with an ORION recommended motor running at normal vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
- Maximum combined output per cylinder (max. vacuum/max. pressure): Pump 1: (55 or lower / 20 or lower), Pump 2: (35 or lower / 50 or lower.)
- Operating environment (inlet air) conditions: air temp: 0 to 40℃, humidity: normal levels (65±20%).
- Allowable intermittent powersupply voltage flucuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
- Please install an overload protection device (such as a thermal relay).
- If detailed specifications are required, please Contact ORION to request a specifications sheet.