CBF Combination Dry PumpSafety Enhanced Design・Low Noise ・ Long Life ・ Environmentally Friendly

CBF1515 / CBF2525 / CBF4040

Continuous Operating Vacuum
Recomm. 60 kPa or less
(V Type)
Continuous Operating Pressure
Recomm. 60 kPa or less
(B Type)
Continuous Combined Operating Vacuum & Pressure
Total Combined Vacuum & Pressure 60 kPa or less
(VBVB Type)
Flow Rate
280 to 685 L/min (60 Hz)
  • Safe and Environmentally Conscious
    CE Marking Certified
  • Quiet Operation
    Noise level reduced by 3 dB (compared with conventional models)
  • Long Life
    Increased 30% with newly developed vane blade material. (Compared with conventional models).
CBF4040
CBF4040-VB

Specifications

Model CBF1515- VB-01B VB-04B ※3 VBVB-01B VBVB-04B ※3
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1 (V): 235/280
Pump 2 (V):235/280
Pump 1 (V,B): 235/280
Pump 2 (V,B):235/280
Continuous Operating Vacuum (V) ※2 kPa (max.) 60 -
Continuous Operating Pressure (B) ※2 kPa (max.) 60 -
Continuous Combined Operating Vaccum & Pressure (VB) kPa - Recom. ※5, Max. ※6
Piping Connection Size   Rc 3/4
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400、415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 3.8/
3.4, 3.4, 3.4
2.0, 1.9, 1.9/
1.7, 1.7, 1.7
3.8/
3.4, 3.4, 3.4
2.0, 1.9, 1.9/
1.7, 1.7, 1.7
Noise Level (50/60 Hz) ※4 dB 62/63 65/66
Motor kW 0.75
Mass kg 37
Model CBF1515- VV-01B BB-01B
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1 (V): 235/280
Pump 2 (V):235/280
Pump 1 (B): 235/280
Pump 2 (B):235/280
Continuous Operating Vacuum (V) ※2 kPa (max.) 60 -
Continuous Operating Pressure (B) ※2 kPa (max.) - 60
Continuous Combined Operating Vaccum & Pressure (VB) kPa -
Piping Connection Size   Rc 3/4
Voltage (50/60 Hz) V 3-phase 200/ 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 3.8/3.4, 3.4, 3.4
Noise Level (50/60 Hz) ※4 dB 61/62 65/66
Motor kW 0.75
Mass kg 37

Model CBF2525- VB-01B VB-04B ※3 VBVB-01B VBVB-04B ※3
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1 (V): 405/480
Pump 2 (V):405/480
Pump 1 (V,B): 405/480
Pump 2 (V,B):405/480
Continuous Operating Vacuum (V) ※2 kPa (max.) 60 -
Continuous Operating Pressure (B) ※2 kPa (max.) 60 -
Continuous Combined Operating Vaccum & Pressure (VB) kPa - Recom. ※5, Max. ※6
Piping Connection Size   Rc 3/4
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400、415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 6.8/
6.4, 6.0, 6.0
3.5, 3.4, 3.4/
3.2, 3.0, 3.0
6.8/
6.4, 6.0, 6.0
3.5, 3.4, 3.4/
3.2, 3.0, 3.0
Noise Level (50/60 Hz) ※4 dB 64/67 67/70
Motor kW 1.5
Mass kg 52
Model CBF2525- VV-01B BB-01B
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1 (V): 405/480
Pump 2 (V):405/480
Pump 1 (B): 405/480
Pump 2 (B):405/480
Continuous Operating Vacuum (V) ※2 kPa (max.) 60 -
Continuous Operating Pressure (B) ※2 kPa (max.) - 60
Continuous Combined Operating Vaccum & Pressure (VB) kPa -
Piping Connection Size   Rc 3/4
Voltage (50/60 Hz) V 3-phase 200/ 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 6.8/6.4, 6.0, 6.0
Noise Level (50/60 Hz) ※4 dB 63/66 67/70
Motor kW 1.5
Mass kg 52

Model CBF4040- VB-01B VB-04B ※3 VBVB-01B VBVB-04B ※3
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1 (V): 575/685
Pump 2 (V):575/685
Pump 1(V,B): 575/685
Pump 2 (V,B):575/685
Continuous Operating Vacuum (V) ※2 kPa (max.) 60 -
Continuous Operating Pressure (B) ※2 kPa (max.) 60 -
Continuous Combined Operating Vaccum & Pressure (VB) kPa - Recom. ※5, Max. ※6
Piping Connection Size   Rc 3/4
Voltage (50/60 Hz) V 3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400, 415/
3-phase 400, 440, 460
3-phase 200/
3-phase 200, 220, 230
3-phase 380, 400、415/
3-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
9.4, 9.2, 9.2
5.3, 5.3, 5.4/
4.7, 4.6, 4.6
10.6/
9.4、9.2、9.2
5.3, 5.3, 5.4/
4.7, 4.6, 4.6
Noise Level (50/60 Hz) ※4 dB 68/70 69/71
Motor kW 2.2
Mass kg 67
Model CBF4040- VV-01B BB-01B
Designed Pumping Capacity (50/60 Hz) ※1 L/min Pump 1 (V): 575/685
Pump 2 (V):575/685
Pump 1 (B): 575/685
Pump 2 (B):575/685
Continuous Operating Vacuum (V) ※2 kPa (max.) 60 -
Continuous Operating Pressure (B) ※2 kPa (max.) - 60
Continuous Combined Operating Vaccum & Pressure (VB) kPa -
Piping Connection Size   Rc 3/4
Voltage (50/60 Hz) V 3-phase 200/ 3-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 10.6/9.4, 9.2, 9.2
Noise Level (50/60 Hz) ※4 dB 67/69 71/73
Motor kW 2.2
Mass kg 67
  1. Designed pumping capacity: Theoretical value calculated from cylinder volume. Refer to "Performance Data" for actual flow rate.
  2. Operable range of vacuum (pressure).
  3. "04" models are special order items.
  4. Operating noise measured on a new pump with an ORION recommended motor running at normal vacuum/pressure conditions. Operating noise levels are from a position of 1 m in front of the unit and at a height of 1 m.
  5. Recommended range of combined vacuum and pump pressures: 60 or lower.
  6. Maximum vacuum/pressure per pump can be any combination of the following (vacuum/pressure): 55/20, 55/30, 40/40, 35/50. The maximum vacuum/pressure of the dry pump indicates the maximum sustainable vacuum/pressure. Do not operate the pump beyond this maximum value. Doing so can reduce the lifespan of the pump and may result in breakdown or an accident.
  • Please consult with your dealer regarding operation in extremely dry environments, as doing so may lead to pump damage.
  • Allowable intermittent power supply voltage fluctuation range is +10% of the specified voltage, allowable sustained supply voltage fluctuation range is +5% of the specified voltage.
  • When using other than the ORION standard motor, follow the electrical guidelines printed on the nameplate of the motor used.
  • Please install an overload protection device (such as a thermal relay).
  • If detailed specifications are required, please Contact ORIONc to request a specifications sheet.

External Dimensions(Units:mm)

dimensions

Performance Data

Vacuum
performance
Blower
performance