Air Station AS135 Series
(Built to order item)
Great improvements in operating noise and heat output for pumps and blowers.

AS135A / AS135W

Built-In Capacity
Built-in model heat dissipation capacity
Max. 13.5 kW (Air Cooled and Water Cooled)
  • Water-cooled and air-cooled models available to best suite your working environment.
    Water-cooled models have nearly zero heat emission. Air-cooled models direct hot air away from your workspace with a duct.
  • Works with your existing configuration of pumps and blowers.
  • 10 to 15 dB sound reduction.
AS135A
AS135A (Air-Cooled) / AS135W (Water-Cooling Model)

Specifications

Model Cooling Type Total Installed Pump Capacity External Dimensions ※1 Air Connections Mass ※2 Operable Ambient Temp. Range
mm Inlet/Outlet
Port Size
Number of
Connections
kW W D H max Qty. kg
AS135A Air-Cooled Estimated total heat dissipation capacity for all installed pumps: 13.5 1500 1077 2099 Rc2 Max: 10 380 5 to 35
AS135W Water-Cooled Estimated total heat dissipation capacity for all installed pumps: 13.5 1500 1077 2411 Rc2 Max: 10 420 5 to 35
Model Cooling Capacity Cooling Water Connection Cooling Water Conditions ※3 Ambient Temp. Ventilation Air Flow
Req. Water Flow Temp. at Inlet Req. Water Pressure m2/h
L/min MPa 50Hz 60Hz
AS135A - - - - - - 3360 3960
AS135W 13.5 Rc1 30 - 40 15 0.2 25 4800 5760
  1. Including warning lamp at top of unit.
  2. Does not include weight of installed pumps.
  3. Cooling capacity varies according to number and types of installed pumps, water flow, and water temperature.
  • Custom models can also be built beyond the above specifications.