KCE Inverter Model Oil-Free Blower Optimum 0.1 MPa (1 kgf/cm2)!

KCE120E-B-01 / KCE120E-B-02
KCE190E-B-01 / KCE190E-B-02
KCE310E-B-01 / KCE310E-B-02
KCE620E-B-01 / KCE620E-B-02
KCE120E-B-AC-01 / KCE120E-B-AC-02
KCE190E-B-AC-01 / KCE190E-B-AC-02
KCE310E-B-AC-01 / KCE310E-B-AC-02

  • -01 Models: Without Casters
  • -02 Models: Include Casters
Pressure
0 to 0.1 MPa (100 kPa)
Motor Output
5.5 to 15 kW
Flow Rate
Up to 10.2 m3/min
  • Energy savings realized thanks to inverter control
KCE120E-B-AC-01 KCE120E-B-AC-02
KCE310E-B-01 / KCE620E-B-02
  • Rotor
    Rotor
  • Low Noise
    Low Noise
  • Inverter
    Inverter
  • Long Life
    Long Life
  • Dry Slide
    Dry Slide
  • Easy Operation
    Easy Operation
Inverter Control and Easy Operation add up to a Comfortable Work Environment
Our "Eco Speed® Control" is effective at automatically keeping electricity consumption to the lowest amount.
eco speed control

Eco Speed Control is offered as standard equipment and automatically reduces the electricity consumption to its minimum effective amount by detecting the user's air load. When operating multiple KCE Blowers, a system upgrade to Multi Eco Speed Control, built with inverter control and a multi-unit control, is possible without a multi-unit control panel.

The KCE Controller and Linked Intelligent LCD Panel Offers Easy Operation

Setting of the blower pressure in increments of 1 kPa is possible. If and when errors occur, they are individually shown on the LCD display. The KCE Controller comes standard with terminals for remote operation input, operation signal, and alarm signal.

Intelligent LCD Panel
Lineup Additions: High Capacity Models with a Built-In Aftercooler Built to Order
 High Capacity Models with a Built-In Aftercooler
  • Please contact us regarding our low dew point spec. (dry air spec.) models.
Low Operating Noise thanks to our New Concept in Noise Prevention Construction and our Contactless Rotor Patented

The synergistic effect of our newly developed 2-layer housing construction and our contactless rotor yields noise reduction of -8 dB.

  • Compared with the unit with no housing.
Low Operating Noise
Optimum Critical Pressure for Air Blow
Can achieve maximum nozzle air speed (to the speed of sound.)

At 0.09 MPa, vapor blown out of the nozzle can attain the speed of sound. No change in flow velocity above 0.09 MPa.

Cost-of-Air Visualization

Cost-of-Air Visualization

Operating Pressure Upper Limit

Operating Pressure Upper Limit
Energy Saving Points
Are you working with depressurized factory air (0.69 MPa)?

[ Upgrade from Factory Air ]]
Air compressors compress air to approximately 1/8 of the starting volume and yet use a lot of energy. If the terminal pressure of air is being reduced to 0.1 MPa on the line before use, then we recommend that the pump be replaced with a KCE blower.
Please contact ORION for basic energy saving examples.

Can be built with a 7 hp motor.
Compare with a 0.1 MPa Air Flow Rate (Oil-Free)

Energy Saving Points

Image of Air-Only (1 m3)

Air-Only

Specifications

Standard Model Spec.
Model KCE120E-B-01 KCE190E-B-01 KCE310E-B-01 KCE380E-B-01 KCE620E-B-01
KCE120E-B-02 KCE190E-B-02 KCE310E-B-02 KCE380E-B-02 KCE620E-B-02
Motor Output kW 3.7 5.5 7.5 11 15
Flow Rate ※1 m3/min 1.95 3.2 5.1 6.4 10.2
m3/h 117 192 308 384 616
Continuous Exhaust Pressure
(50/60Hz)※2
MPa 0.1 or lower 0.1 or lower 0.1/0.06 or lower 0.1 or lower 0.1/0.06 or lower
kPa 100 or lower 100 or lower 100/60 or lower 100 or lower 100/60 or lower
Operating Noise Level
(50Hz/60Hz)※3
dB - 73 71/73 76 76/78
Piping Connection Size   Rc1 1/2 Rc2 Rc3
Mass ※4 kg 340 365 435 575 860
Motor Rated Power Supply / Frequency ※5   Three-phase 200 V, 50/60 Hz
Output /
No. of Poles
× No. of Units
  3.7 kW / 2P × 1 Unit 5.5kW / 2P × 1 Unit 7.5kW / 2P × 1 Unit 5.5kW / 2P × 2 Unit 7.5kW / 2P × 2 Unit
Specifications   Top Runner compliant, high efficiency motor
Installation Environment Installation Location   Indoors
Permissible Ambient Temp ※6 5 to 40
Permissible Ambient Humidity   65 ±20%RH(JIS Z8703)
Operable Elevation※7 m 1000 or lower
Control Method   Built-in load detecting automatic speed control circuit.
Automatic Speed Control Range Hz 20 to 60
  1. The flow rate is the theoretical value based on the designed pumping capacity. See the Power Graphs for the actual flow rate.
  2. Indicates the upper limit of exhaust pressure under sustained blower operation.
  3. The operating noise level is only an actual measured value of when the unit was operating at its normal exhaust pressure and is not a guaranteed value.
  4. 02 models include casters and have an additional mass of 5 kg.
  5. The allowable intermittent power supply voltage fluctuation range is ±10%, and the allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
  6. There may be a high pitch sound if the ambient temperature is near 0 ℃ when starting, but such noise will go away after a short time and does not indicate abnormal operation. Please contact ORION if the noise continues longer than 30 minutes.
  7. Please consult ORION regarding operation at altitudes higher than 1000 m.
Aftercooler Spec. Built to Order
Model KCE120E-B-AC-01 KCE190E-B-AC-01 KCE310E-B-AC-01
KCE120E-B-AC-02 KCE190E-B-AC-02 KCE310E-B-AC-02
Motor Output kW 3.7 5.5 7.5
Flow Rate ※1 m3/min 1.95 3.2 5.1
m3/h 117 192 308
Continuous Exhaust Pressure (50/60 Hz) ※2 MPa 0.1 or lower 0.1 or lower 0.1/0.06 or lower
kPa 100 or lower 100 or lower 100/60 or lower
Operating Noise Level (50/60 Hz) ※3 dB - 73 71/73
Piping Connection Size   Rc1 1/2 Rc2
Mass ※4 kg - 380 485
Motor Rated Power Supply / Frequency ※5   Three-phase 200 V, 50/60 Hz
Output / No. of Poles × No. of Units   3.7 kW / 2P × 1 Unit 5.5kW / 2P × 1 Unit 7.5kW / 2P × 1 Unit
Specifications   Top Runner compliant, high efficiency motor
Installation Environment Installation Location   Indoors
Permissible Ambient Temp※6 5 to 40
Permissible Ambient Humidity   65 ±20%RH(JIS Z8703)
Operable Elevation ※7 m 1000 or lower
Control Method   Built-in load detecting automatic speed control circuit.
Automatic Speed Control Range Hz 20 to 60
  1. The flow rate is the theoretical value based on the designed pumping capacity. See the Power Graphs for the actual flow rate.
  2. Indicates the upper limit of exhaust pressure under sustained blower operation.
  3. The operating noise level is only an actual measured value of when the unit was operating at its normal exhaust pressure and is not a guaranteed value.
  4. 02 models include casters and have an additional mass of 5 kg.
  5. The allowable intermittent power supply voltage fluctuation range is ±10%, and the allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
  6. There may be a high pitch sound if the ambient temperature is near 0 ℃ when starting, but such noise will go away after a short time and does not indicate abnormal operation. Please contact ORION if the noise continues longer than 30 minutes.
  7. Please consult ORION regarding operation at altitudes higher than 1000 m.