RAV Precision Temperature Control Air Dryer Best Choice for Precision Processing Equipment / Precision Measurement Instruments / Localized Temperature Control, Etc.

RAV400B-HP / RAV400B-HPF
RAV600B-HP / RAV600B-HPF

Operating Air Flow
100 to 900 L/min
Temperature Control Precision
±0.1℃
Temperature Setting Range
15 to 30℃
Pressure Setting Range
0.15 to 0.85MPa
  • High precision temperature control of compressed air and temperature control precision of ±0.1 ℃.
  • Using (heaterless) Heat Pump Balance® Control, at least 70% in energy savings is possible over systems using heater PID control.

※ Heat Pump Balance Control® is a registered trademark of ORION.

Intelligent Monitor
Intelligent Monitor
Heat Pump Balance Control
Heat Pump Balance Control
Air Cooled
Air Cooled
Temp Control
Temp Control
RAV600A-HPF

RAV600B-HPF

Specifications

  RAV400B-HP RAV400B-HPF
Model A1 A2 A1 A2
Air Processing Conditions Air Processing Capacity
(50/60Hz)※3
L/min 400(ANR)
Inlet Air Pressure
(Gauge Pressure)
MPa 0.70
Inlet Air Temperature 35
Outlet Air Temperature Range, Precision※4 15 to 30, Set value ± 0.1 ℃
Outlet Pressure Dew Point※2 10※1
Ambient Temperature 30
Operating Range Operating Fluid Compressed air
Operable Air Flow L/min 100 to 500 (ANR)
Inlet Air Temperature 5 to 40
Ambient Temperature 15 to 35
Operating Range
(Gauge pressure)
MPa 0.2 to 1.0
Pressure Setting Range MPa 0.15 to 0.85
External Dimensions (H×D×W) mm 498×470×270 498×600×270
Mass kg 31 32
Air Outlet Connection Pipe Size B・A R 1/2・15
Electrical Specifications Power Supply (50/60Hz)(±10%) V A1: Single-phase 100/100, 110 A2: Single-phase 200, 220/200, 220
Power Consumption kW 0.26/0.28,0.31 0.26,0.29/0.27,0.30 0.26/0.28,0.31 0.26,0.29/0.27,0.30
Current A 3.0/2.8,2.8 1.4,1.6/1.3,1.3 3.0/2.8,2.8 1.4,1.6/1.3,1.3
Equipment Specifications Refrigerated Dryer Control Method Heat Pump Balance Control
Mist Filter Filtration Degree - 0.01µm
Collection Efficiency - 99.999%
Output Oil Concentration※6 - 0.01wt ppm
Filter Element Replacement Period※5 - 1 year, or when the pressure loss is 0.07 MPa
Filter Element Model - EMS150
Drain Release Unit Solenoid Valve
Temperature Display, Temperature Sensor※7 Digital display, platinum resistance thermometer (JIS B Class)
Regulator Piston type
Refrigerant R-134a
Chiller Compressor Output W 300
  RAV600B-HP RAV600B-HPF
Model A1 A2 A1 A2
Air Processing Conditions Air Processing Capacity (50/60 Hz)※3 L/min 600(ANR)
Inlet Air Pressure
(Gauge pressure)
MPa 0.70
Inlet Air Temperature 35
Outlet Air Temperature Range, Precision※4 15 to 30 (Set value ± 0.1 ℃)
Outlet Pressure Dew Point※2 10※1
Ambient Temperature 30
Operating Range Operating Fluid Compressed air
Operable Air Flow L/min 200 to 900(ANR)
Inlet Air Temperature 5 to 40
Ambient Temperature 15 to 35
Operating Range
(Gauge Pressure)
MPa 0.2 to 1.0
Pressure Setting Range MPa 0.15 to 0.85
External Dimensions (H×D×W) mm 568×470×270 568×600×270
Mass kg 33 34
Air Outlet Connection Pipe Size B・A R 1/2・15
Electrical Specifications Power Supply (50/60Hz)(±10%) V A1: Single-phase 100/100, 110 A2: Single-phase 200, 220/200, 220
Power Consumption kW 0.35/0.35,0.41 0.33,0.36/0.37,0.40 0.35/0.35,0.41 0.33,0.36/0.37,0.40
Current A 4.1/3.6,3.9 2.0,2.3/1.8,1.8 4.1/3.6,3.9 2.0,2.3/1.8,1.8
Equipment Specifications Refrigerated Dryer Control Method Heat Pump Balance Control
Mist Filter Filtration Degree - 0.01µm
Collection Efficiency - 99.999%
Output Oil Concentration※6 - 0.01wt ppm
Filter Element
Replacement Period※5
- 11 year, or when the pressure loss is 0.07 MPa
Filter Element Model - EMS150
Drain Release Unit Solenoid Valve
Temperature Display, Temperature Sensor※7 Digital display, platinum resistance thermometer (JIS B Class)
Regulator Piston type
Refrigerant R-134a
Chiller Compressor Output W 400
  1. Standard product specifications are for indoor use.
  2. Outlet air pressure dew point value is based on a conversion of the air dryer outlet air pressure and will fluctuate depending on the quantity of supersaturated water in the intake air. If compressed air flowing into the product contains supersaturated water vapor, it is recommended that a drain filter be installed before the product.
  3. Air processing capacity figures are based on ANR (atmospheric pressure, 20 ℃, 75% RH).
  4. Temperature precision is at a single output port, and that of the precision of the display device, when the inlet temperature and air flow are stable.
  5. The filter element needs to be replaced when whichever of these first occurs. (The optional DG-50(B) pressure gauge can be used to assist in pressure management.)
  6. The inlet oil concentration is 3 wt ppm or lower, excluding oil vapor, in accordance with the method described in ISO8573-2, "Test Methods for oil Aerosol Content".
  7. If there is a lot of foreign matter (solid particulate) in the supply air, then install an air filter (5 µm equiv.) on the intake side piping before the product.