PAP Water-Cooled Temperature Controlled Precision Air ProcessorCombining Energy Savings & High Precision! The Industry-Leading PAP Series
PAP05A1-W / PAP05A1-FW
PAP10C-WNEW/PAP10C-FWNEW
PAP20C-WNEW/PAP20C-FWNEW
PAP40B-W / PAP40B-FW
- Air Processing Capacity
- 3 to 40 m3/min
- Humidity Control Precision
- ±0.1℃
- Temperature Setting Range
- 18 to 30℃
Special Order Product
Noise Reducing Intake Duct / Circulation Intake Chamber
Ventilation Air Out Chamber / Incl. Humidification Display
Table of Special Order Items Here
- Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
Specifications
PAP05A1-W | PAP05A1-FW | |||
---|---|---|---|---|
Performance | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
Temperature Control Precision ※2 | ℃ | ±0.1 | ||
Cooling + Heating Output (50/60 Hz) | kW | 3.2/3.2 | ||
(Maximum cooling capacity) | (kW) | (2.0) | ||
Rated Processing Air Flow | m3/min | 3 to 5 | ||
Maximum External Static Pressure ※3 | Pa | 410/660 | 300/620 | |
Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 35 , 30 to 70 | |
Temperature Gradient at Intake | ℃/h | Within ±2 | ||
Humidity Gradient at Intake | %/h | Within ±5 | ||
Cooling Water Temp Gradient | ℃/h | Within ±5 | ||
External Dimensions (HxDxW) ※4 | mm | 1489×586×538 | ||
Product Mass | kg | 120 | 130 | |
Controlled Air Outlet Port | mm | Φ100 | Φ100 with built-in HEPA filter. |
|
Cooling Water | Rate of Supply ※6 | m3/h | 1.0 | |
Supply Temp Range | ℃ | 15 to 32 | ||
Supply Pressure | MPa | 0.69 or lower | ||
Inlet/Outlet Pressure Difference | MPa | 0.2 or higher | ||
Connection Port Size | Rc1/2 | |||
Electrical Specifications | Power Source ※7 | V(Hz) | Three-phase 200 ±10% (50/60) | |
Power Consumption (50/60 Hz) ※8 | kW | 1.2/1.3 | ||
Electric Current ※8 | A | 4.5/5.2 | ||
Power Supply Capacity ※9 | kVA | 1.8 | ||
Noise Level (50/60 Hz) ※10 | dB | 68/71 | ||
Operation Control Method | Heat Pump Balance Control | |||
Refrigerant | R410A | |||
Chiller Compressor Output | kW | 0.7 |
PAP10C-W | PAP10C-FW | |||
---|---|---|---|---|
Performance | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
Temperature Control Precision ※2 | ℃ | ±0.1 | ||
Cooling + Heating Output (50/60 Hz) | kW | 6.5/6.5 | ||
(Maximum cooling capacity) | (kW) | (4.0) | ||
Rated Processing Air Flow | m3/min | 7 to 10 | ||
Maximum External Static Pressure ※3 | Pa | 180 | 570 | |
Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 35 , 30 to 70 | |
Temperature Gradient at Intake | ℃/h | Within ±10 | ||
Humidity Gradient at Intake | %/h | Within ±5 | ||
Cooling Water Temp Gradient | ℃/h | Within ±5 | ||
External Dimensions (HxDxW) ※4 | mm | 1515×720×570 | 1855×720×570 | |
Product Mass | kg | 163 | 205 | |
Controlled Air Outlet Port | mm | Φ148 | Φ148 with built-in HEPA filter box ※5 |
|
Cooling Water | Rate of Supply ※6 | m3/h | 1.2 | |
Supply Temp Range | ℃ | 15 to 32 | ||
Supply Pressure | MPa | 0.69 or lower | ||
Inlet/Outlet Pressure Difference | MPa | 0.2 or higher | ||
Connection Port Size | Rc3/4 | |||
Electrical Specifications | Power Source ※7 | V(Hz) | Three-phase 200 ±10% (50/60) | |
Power Consumption (50/60 Hz) ※8 | kW | 1.5 | ||
Electric Current ※8 | A | 4.6 | 4.8 | |
Power Supply Capacity ※9 | kVA | 1.6 | 1.7 | |
Noise Level (50/60 Hz) ※10 | dB | 64 | 73 | |
Operation Control Method | Heat Pump Balance Control | |||
Refrigerant | R32 | |||
Chiller Compressor Output | kW | 0.85 |
PAP20C-W | PAP20C-FW | |||
---|---|---|---|---|
Performance | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
Temperature Control Precision ※2 | ℃ | ±0.1 | ||
Cooling + Heating Output (50/60 Hz) | kW | 13.0/13.0 | ||
(Maximum cooling capacity) | (kW) | (8.0) | ||
Rated Processing Air Flow | m3/min | 13 to 20 | ||
Maximum External Static Pressure ※3 | Pa | 110 | 540 | |
Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 35 , 30 to 70 | |
Temperature Gradient at Intake | ℃/h | Within ±10 | ||
Humidity Gradient at Intake | %/h | Within ±5 | ||
Cooling Water Temp Gradient | ℃/h | Within ±5 | ||
External Dimensions (HxDxW) ※4 | mm | 1515×860×640 | 1855×860×640 | |
Product Mass | kg | 210 | 260 | |
Controlled Air Outlet Port | mm | Φ198 | Φ198 with built-in HEPA filter box ※5 |
|
Cooling Water | Rate of Supply ※6 | m3/h | 2.2 | |
Supply Temp Range | ℃ | 15 to 32 | ||
Supply Pressure | MPa | 0.69 or lower | ||
Inlet/Outlet Pressure Difference | MPa | 0.2 or higher | ||
Connection Port Size | Rc3/4 | |||
Electrical Specifications | Power Source ※7 | V(Hz) | Three-phase 200 ±10% (50/60) | |
Power Consumption (50/60 Hz) ※8 | kW | 3.1 | 3.0 | |
Electric Current ※8 | A | 10.0 | 10.3 | |
Power Supply Capacity ※9 | kVA | 3.5 | 3.6 | |
Noise Level (50/60 Hz) ※10 | dB | 67 | 71 | |
Operation Control Method | Heat Pump Balance Control | |||
Refrigerant | R32 | |||
Chiller Compressor Output | kW | 1.85 |
PAP40B-W | PAP40B-FW | |||
---|---|---|---|---|
Performance | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
Temperature Control Precision ※2 | ℃ | ±0.1 | ||
Cooling + Heating Output (50/60 Hz) | kW | 22.0/22.0 | ||
(Maximum cooling capacity) | (kW) | (16.0) | ||
Rated Processing Air Flow | m3/min | 25 to 40 | ||
Maximum External Static Pressure ※3 | Pa | 300/300 | 1000/1000 | |
Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 35 , 30 to 70 | |
Temperature Gradient at Intake | ℃/h | Within ±2 | ||
Humidity Gradient at Intake | %/h | Within ±5 | ||
Cooling Water Temp Gradient | ℃/h | Within ±5 | ||
External Dimensions (HxDxW) ※4 | mm | 1800×1200×900 | 2323×1200×900 | |
Product Mass | kg | 440 | 540 | |
Controlled Air Outlet Port | mm | Φ350 | Φ350 with built-in HEPA filter box ※5 |
|
Cooling Water | Rate of Supply ※6 | m3/h | 3.0 | |
Supply Temp Range | ℃ | 15 to 32 | ||
Supply Pressure | MPa | 0.69 or lower | ||
Inlet/Outlet Pressure Difference | MPa | 0.2 or higher | ||
Connection Port Size | Rc1 | |||
Electrical Specifications | Power Source ※7 | V(Hz) | Three-phase 200 ±10% (50/60) | |
Power Consumption (50/60 Hz) ※8 | kW | 6.0 | ||
Electric Current ※8 | A | 24.0 | ||
Power Supply Capacity ※9 | kVA | 8.3 | ||
Noise Level (50/60 Hz) ※10 | dB | 75/75 | 83/83 | |
Operation Control Method | Heat Pump Balance Control | |||
Refrigerant | R410A | |||
Chiller Compressor Output | kW | 3.0 |
- The temperature control range noted does not necessarily indicate the actual possible controllable range. The range of temperature control depends on the condition of the air supplied at the intake.
- Values indicated are for when the intake air temperature and humidity, and supply water temperature and flow rate are stable. Controller display precision at a single discharge port location.
- The external static pressure at the controlled air outlet side when operating at the maximum rated air flow.
- Height includes discharge port.
- The HEPA filter box is shipped separate from the product main unit and must be assembled on site.
- When operating at the maximum air flow and at the highest cooling capacity, and when the difference between the cooling water inlet and outlet ports is 6.5 ℃.
- The maximum allowable source voltage phase imbalance is ±3%.
- Maximum value within the range of the product's specifications.
- The figure noted is when operating at the highest capacity of the specified operating range.
- The noise level may be lowered by installing the Noise Reducing Duct.