PAP Air-Cooled Temperature Controlled Precision Air ProcessorCombining Energy Savings & High Precision! The Industry-Leading PAP Series
PAP05A1 / PAP05A1-F
PAP10C / PAP10C-SR
PAP20A / PAP20A-F
- Air Processing Capacity
- 3 to 20 m3/min
- Temperature Control Precision
- ±0.1℃
- Temperature Setting Range
- 18 to 30℃
Special Order Product
Noise Reducing Intake Duct / Circulation Intake Chamber
Ventilation Air Out Chamber / Incl. Humidification Display
Table of Special Order Items Here
- Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
refrigerant circuitis 2 years
from the date of purchase
(or 10,000 hours of operating time).
-
Intelligent Monitor -
Heat Pump Balance Control -
Capacity Control -
HEPA Filter (F Type) -
Air Cooled -
Water Cooled -
Temperature Control -
Humidity Control -
IoT
Specifications
| PAP05A1 | PAP05A1-F | |||
|---|---|---|---|---|
| Performance Specifications | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
| Temperature and Humidity Control Precision ※2 | ℃ | ±0.1 | ||
| Cooling / Heating Output (50/60 Hz) | kW | 2.3/2.6 | ||
| (Maximum cooling capacity) (50/60 Hz) | (kW) | (1.6)/(1.8) | ||
| Rated Processing Air Flow | m3/min | 3 to 5 | ||
| Maximum External Static Pressure ※3 | Pa | 110 | 620 | |
| Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 35,30 to 70 | |
| Temperature Gradient at Intake | ℃/h | Within ±1 | ||
| Humidity Gradient at Intake | %/h | Within ±5 | ||
| External Dimensions (HxDxW) ※4 | mm | 1140×700×600 | 1423×700×600 | |
| Mass | kg | (130) | (155) | |
| Controlled Air Outlet Port (O.d.) | mm | Φ100 | Φ100 with built-in HEPA filter. |
|
| Power Specifications | Power Supply ※6 | V(Hz) | Three-phase 200 ±10% (50/60) | |
| Power Consumption ※7 | kW | 1.4 | ||
| Electric Current ※7 | A | 6.2 | ||
| Power Supply Capacity ※8 | kVA | 2.2 | ||
| Noise Level (50/60 Hz) ※9 | dB | 66/66 | 71/71 | |
| Legal Refrigeration Tonnage (50/60 Hz) | 0.39 | |||
| Operation Control Method | Heat Pump Balance Control | |||
| Refrigerant ※10 | R410A | |||
| Legal Refrigeration Tonnage (50/60 Hz) | kg | 0.85 | ||
| Compressor Output | kW | 0.7 | ||
| PAP10C | PAP10C-SR | |||
|---|---|---|---|---|
| Performance Specifications | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
| Temperature and Humidity Control Precision ※2 | ℃ | ±0.1 | ||
| Cooling / Heating Output (50/60 Hz) | kW | 4.7/5.3 | ||
| (Maximum Cooling Output) (50/60 Hz) | (kW) | (3.2)/(3.6) | ||
| Rated Processing Air Flow | m3/min | 7 to 10 | ||
| Maximum External Static Pressure ※3 | Pa | 180 | ||
| Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 40, 30 to 70 | |
| Ambient Air | ℃,% | - | 5 to 40, 30 to 70 | |
| Temperature Gradient at Intake | ℃/h | Within ±5 | ||
| Humidity Gradient at Intake | %/h | Within ±5 | ||
| External Dimensions (HxDxW) ※4 | mm | 1445×720×600 | ||
| Mass | kg | 166 | 161 | |
| Controlled Air Outlet Port (O.d.) | mm | Φ148 | ||
| Power Specifications | Power Supply ※6 | V(Hz) | Three-phase 200 ±10% (50/60) | |
| Power Consumption ※7 | kW | 2.0 | ||
| Electric Current ※7 | A | 7.7 | ||
| Power Supply Capacity ※8 | kVA | 2.7 | ||
| Noise Level (50/60 Hz) ※9 | dB | 68 | 73/73 | |
| Legal Refrigeration Tonnage (50/60 Hz) | 0.53 | |||
| Operation Control Method | Heat Pump Balance Control | Heat Pump Balance Control(Super Reheat Type) | ||
| Refrigerant ※10 | R32 | |||
| Refrigerant Filling Volume | kg | 1.0 | 0.65 | |
| Compressor Output | kW | 1.85 | ||
| PAP20A | PAP20A-F | |||
|---|---|---|---|---|
| Performance Specifications | Possible Temperature Setting Range ※1 | ℃ | 18 to 30 | |
| Temperature and Humidity Control Precision ※2 | ℃ | ±0.1 | ||
| Cooling / Heating Output (50/60 Hz) | kW | 9.4/10.5 | ||
| (Maximum Cooling Output) (50/60 Hz) | (kW) | (6.5)/(7.2) | ||
| Rated Processing Air Flow | m3/min | 13 to 20 | ||
| Maximum External Static Pressure ※3 | Pa | 250 | 690 | |
| Environmental Conditions | Ambient Temp and Humidity Range (Intake air) ※1 | ℃,% | 15 to 35,30 to 70 | |
| Temperature Gradient at Intake | ℃/h | Within ±1 | ||
| Humidity Gradient at Intake | %/h | Within ±5 | ||
| External Dimensions (HxDxW) ※4 | mm | 1610×1150×770 | 2010×1150×770 | |
| Mass | kg | (290) | (365) | |
| Controlled Air Outlet Port (O.d.) | mm | Φ200 | Φ200 HEPA filter built in ※5 |
|
| Power Specifications | Power Supply ※6 | V(Hz) | Three-phase 200 ±10% (50/60) | |
| Power Consumption ※7 | kW | 3.9 | ||
| Electric Current ※7 | A | 14.9 | ||
| Power Supply Capacity ※8 | kVA | 5.2 | ||
| Noise Level (50/60 Hz) ※9 | dB | 69/69 | 76/76 | |
| Legal Refrigeration Tonnage (50/60 Hz) | 1.25 | |||
| Operation Control Method | Heat Pump Balance Control | |||
| Refrigerant ※10 | R410A | |||
| Refrigerant Filling Volume | kg | 1.8 | ||
| Compressor Output | kW | 3.0 | ||
- The temperature control range noted does not necessarily indicate the actual controllable range possible. The range of temperature control depends on the condition of the air supplied at the intake.
- When the air temperature and humidity is stable at the air intake. Noted precision is based on measurement by the internal controller at a single air outlet point.
- The noted external static pressure is when the controlled air is regulated at the outlet to produce the maximum rated processing airflow.
- Height includes outlet port.
- The HEPA filter box is shipped in a separate package from the main unit and must be installed on-site.
- Source voltage phase unbalance should be less than ±3 %.
- Maximum value within the range of unit specifications.
- The figure noted is when the equipment is operating at the highest capacity of its normal operating range.
- Noise level can be decreased by installing a noise-reducing intake duct.
- This product contains a refrigerant gas that is slightly flammable. When installing indoors, ensure there is adequate ventilation in order to prevent combustion in cases of a refrigerant leak, and also take measures to keep fire away from the area.
- All ducting should be insulated and ducting length should be kept as short as possible. (5 m or shorter recommended.)