Air Processor Circulation Type High Precision Temperature and Humidity Control Equipment
AP-750M-E1 / AP-750MV-E1 /
AP-750MVK-E1
AP-1500M-E1 / AP-1500MV-E1 /
AP-1500MVK-E1
- Temperature Setting Range
- 5 to 70℃
- Humidity Setting Range
- 30 to 90%
(Humidity control type)
- Localized precision air processing units that can be used to fill each of the needs of various industrial fields.
- The circulating type air circuit easily enables environments from low to high temperatures.
Features
Compact Design
The environment box (testing chamber) can be easily replaced or moved according to your needs.
Three Functions to Choose From
3 functions of Temperature Control, Humidity Control, and Purification (special order) offer a total response to your local air space needs.
Temperature and Humidity Control Range Chart (AP-750MVK-E1 and AP-1500MVK-E1)
Operating Conditions
- Power Source: Three-phase, 200 V, 60 Hz
- Ambient Temperature and Humidity: 25 ℃ / 50%
- Circuit: Full-Circulation Method
Specifications
AP-750M-E1 | AP-750MV-E1 | AP-750MVK-E1 | |||
---|---|---|---|---|---|
Performance | Temperature Control Range | ℃ | 5 to 35 | 5 to 70 | 5 to 70 (15 to 70 when under humidity control) |
Humidity Control Range ※1 | % | - | 30 to 90 (When temp is 40 to 60 ℃) |
||
Control Precision ※2 | ℃,% | ±0.5 | ±0.5,±3 | ||
Control Method | Digital Setting, Digital Display, PID Heater Control | ||||
Cooling Capacity ※3 | kW | 1.5/1.75 | |||
Air Flow (50/60 Hz) | m3/min | 4 to 6 / 4 to 7 | |||
Operable Ambient Temperature Range | ℃,% | 15 to 35 | |||
Outlet Connection Port | Air Outlet Port: Φ100 (Incl. companion flange) | ||||
Electrical Specifications | Power Supply | V(Hz) | Three-phase 200±10% (50/60) | ||
Maximum Operating Current | A | 18 | 27 | ||
Maximum Operating Power Consumption | kW | 5.7 | 9.0 | ||
Circuit Breaker | Built-In | ||||
Refrigerant | R407C | ||||
Chiller Compressor Output | kW | 0.65 | |||
Product Mass | kg | 120 | 130 | ||
External Dimensions (HxDxW) | mm | 1044×548×660 |
AP-1500M-E1 | AP-1500MV-E1 | AP-1500MVK-E1 | |||
---|---|---|---|---|---|
Performance | Temperature Control Range | ℃ | 5 to 35 | 5 to 70 | 5 to 70 (15 to 70 when under humidity control) |
Humidity Control Range ※1 | % | - | 30 to 90 (When temp is 40 to 60 ℃) |
||
Control Precision ※2※2 | ℃,% | ±0.5 | ±0.5,±3 | ||
Control Method | Digital Setting, Digital Display, PID Heater Control | ||||
Cooling Capacity ※3 | kW | 3.25 | |||
Air Flow (50/60 Hz) | m3/min | 10 to 13 / 10 to 15 | |||
Operable Ambient Temperature Range | ℃,% | 15 to 35 | |||
Outlet Connection Port | Air Outlet Port: Φ150 (Incl. companion flange) | ||||
Electrical Specifications | Power Supply | V(Hz) | Three-phase 200±10% (50/60) | ||
Maximum Operating Current | A | 37 | 58 | ||
Maximum Operating Power Consumption | kW | 11.5 | 19.0 | ||
Circuit Breaker | Built-In | ||||
Refrigerant | R407C | ||||
Chiller Compressor Output | kW | 1.4 | |||
Product Mass | kg | 195 | 205 | ||
External Dimensions (HxDxW) | mm | 1374×618×753 |
- When under temperature and humidity control, refer to the "Temperature and Humidity Control Range Chart" shown above.
- During times of no load, no sample, operating at the rated voltage, temperature (humidity) taken from air at the air outlet/inlet ports for a short time.
- Maximum air flow, control temp: 25 ℃, ambient temp: 25 ℃. (Will differ while under humidity control.)
- Never operate with explosive or combustible substances, nor with test substances that may contain any such explosive or combustible compounds.
- Install in a location free from the effects of corrosive gases (especially those harmful to copper and stainless steel.)