Heavy Duty RAX-J Series Air Dryer Operation possible even in ambient temperatures of 48 °C. Uses a stainless steel shell heat exchanger.

Air Cooled
RAX75J~RAX190J /
RAX240F / RAX300F-E~RAX380F-E
Water Cooled
RAX75J-W~RAX190J-W /
RAX240F-W / RAX300F-WE~RAX450F-WE

Air Processing Capacity
Air Cooled
12.1/13.4 to 59/69 m3/min
Water Cooled
12.1/14 to 83/98 m3/min
Intake Air Temperature
5 to 60 °C
Compatible Air Compressor
Air Cooled
75 to 380 kW
Water Cooled
75 to 450 kW
RAX75J / RAX120J / RAX300F-E
RAX75J / RAX120J / RAX300F-E
RAX75J~190J-W Features
The Air Dryer that Keeps Going!

Works in Ambient Temps. to 48 °C

Works in Ambient Temps. to 48 °C
Increased Air Processing Capacity
Increased Air Processing Capacity
  • Compared with previous 50 Hz, air cooled models.
Space Saving & Compact

Product Volume and Installation Space Reduced by 30% (Compared with previous models)

Front Intake / Top Exhaust
Can Be Closed-in on Left or Right Side
Can Be Closed-in on Left or Right Side
Left or Right
Drain Trap Installation
Drain Trap Installation on Right or Left
  • Note that right-side installation requires optional parts.
Can be Installed Against Left, Right, and Rear Walls
Can be Installed Against Left, Right, and Rear Walls
  • Right-side only on RAX150J(-W) and RAX190J(-W) models.
RAX240F~450F-WE Features
Saves energy by controlling the number of cooling compressors. (Energy saving type)

Automatic single refrigerant cycle operation (50%) or double refrigerant cycle operation (100%) based on processed air load. Up to 50% savings on electricity bill possible.

Operates with low loads below 0.01 MPa. (RAX240F / RAX240F-W)

Low pressure-loss (pressure-drop) heat exchanger sports little clogging even after long operating hours.

0.69MPa 0.006~0.01MPa
0.98 MPa (Max. operating pressure) 0.004~0.008MPa
  • Noted flow rate values is for 50 Hz.
Easy Maintenance and Set-Up

(1) Exhaust duct may be installed above the dryer, saving precious floor space. (Air-cooled models)

(2) Design allows front access to main parts for maintenance and inspection.

Easy Maintenance and Set-Up
  • If space is limited, the right side of the dryer can be placed against a wall.

Specifications

RAX75J~RAX190J
Model Air Cooled
RAX 75J 90J 120J 150J 190J
Air Processing Capacity (50/60 Hz) m3/min 12.1/13.4 17.3/20.1 22.1/25.3 27.5/32.0 34.1/40.5
Inlet Air Temp. Range / Outlet Air Dew Point 5 to 60 / Under pressure: 10
Working Fluid / Operable Ambient Temp. Range Compressed air / 2 to 48
Operating Pressure Range (Gauge pressure) MPa 0.29 to 0.98
External Dimensions Height mm 1140 1286 1332
Depth mm 1081 1244 1290
Width mm 470 700
Mass kg 146 186 205 279 286
Auto
Drain
Trap
Model AD-5
Drain Release Port Size Rc1/2
Air Inlet/Outlet Connection Port Size R2 2 1/2B 65A flange 3B 80A flange
Electrical Specifications Voltage (50/60 Hz) V Three-phase 200/200,220
Power Consumption (50/60 Hz) kW 2.5/3.0,3.0 3.0/3.9,3.9 4.1/5.2,5.2 5.7/7.5,7.4
Electric Current (50/60 Hz) A 9.5/9.5,9.4 11.5/12.0,12.0 14.0/16.5,15.5 20.5/24.5,22.5
Power Supply Capacity kVA 5.0 6.3 7.8 10.4
Breaker Capacity A 20 30 40
Refrigerant R-410A
Chiller Compressor Output kW 1.9 2.2 3.0 4.2
Operating Noise Level (50/60 Hz)※1 dB(A) 67/70 70/73 71/74
  1. Operating noise level measured from a position of 1 m in front and at a height of 1 m.
  • Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
  • Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
  • Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
  • Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
  • Air inlet/outlet connection companion flanges are not included.
  • Compatible flange: JIS10KFF equiv.
  • RAX75J~RAX190J models include eye bolts (suspension bolts).
  • Models with secondary heat exchangers made with stainless steel piping are available. Please inquire for further information.
  • Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
RAX75J-W~RAX190J-W
Model Water Cooled
RAX 75J-W 90J-W 120J-W 150J-W 190J-W
Air Processing Capacity (50/60 Hz) m3/min 12.1/14.0 17.3/20.1 22.1/25.3 27.5/32.0 35.0/41.0
Inlet Air Temp. Range / Outlet Air Dew Point 5 to 60 / Under pressure: 10
Working Fluid / Operable Ambient Temp. Range Compressed air / 2 to 48
Operating Pressure Range (Gauge pressure) MPa 0.29 to 0.98
Cooling Water Water Temp. 32
Water Flow Rate※1 m3/h 1.7 2.8 2.9 3.0 3.2
External Dimensions Height mm 1140 1286 1332
Depth mm 1081 1244 1290
Width mm 470 700
Mass kg 140 183 203 270 277
Auto
Drain
Trap
Model AD-5
Drain Release Port Size Rc1/2
Air Inlet/Outlet Connection Port Size R2 2 1/2B 65A flange 3B 80A flange
Cooling Water Inlet/Outlet Connection Port Size メスネジ Rp3/4
Electrical Specifications Voltage (50/60 Hz) V Three-phase 200/200,220
Power Consumption (50/60 Hz) kW 1.7/2.0,2.0 2.1/2.6,2.5 3.5/4.2,4.2 4.7/6.2,6.1
Electric Current (50/60 Hz) A 8.0/8.0,8.0 8.6/9.4,8.9 11.5/12.0,11.0 15.5/17.0,16.0
Power Supply Capacity kVA 4.0 5.2 7.1 9.8
Breaker Capacity A 15 20 30 40
Refrigerant R-410A
Chiller Compressor Output kW 1.9 2.2 3.0 4.2
Operating Noise Level (50/60 Hz)※2 dB(A) 54/56 56/56 57/57 57/58
  1. Cooling water flow rate is for 60 Hz.
  2. Operating noise level measured from a position of 1.5 m in front and at a height of 1 m.
  • Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
  • Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
  • Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
  • Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
  • Air inlet/outlet connection companion flanges are not included.
  • Flange: JIS10KFF equiv.
  • RAX75J-W~190J-Wはアイボルト(吊りボルト)付です。
  • RAX75J-W~RAX190J-W models include eye bolts (suspension bolts).
  • Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
RAX240F / RAX300F-E / RAX380F-E
Model Air Cooled
Standard Energy Saving
RAX 240F 300F-E 380F-E
Air Processing Capacity (50/60 Hz) m3/min 38/45 47/55 59/69
Inlet Air Temp. Range / Outlet Air Dew Point 5 to 60 / Under pressure: 10
Working Fluid / Operable Ambient Temp. Range Compressed air / 2 to 40
Operating Pressure Range (Gauge pressure) MPa 0.29~0.98 0.29~0.93
External Dimensions Height mm 1583 1650
Depth mm 905 1100
Width mm 1969 2020
Mass kg 555 790 870
Auto
Drain
Trap
Model AD-5
Drain Release Port Size Rc1/2
Air Inlet/Outlet Connection Port Size 4B 100A flange 5B 125A flange
Electrical Specifications Voltage (50/60 Hz) V Three-phase 200/200,220
Power Consumption (50/60 Hz) kW 4.6/5.7,5.6 5.9/6.8,6.8 8.6/10.1,10.0
Electric Current (50/60 Hz) A 17.9/19.2,19.1 19.9/22.3,21.2 26.4/29.4,28.9
Power Supply Capacity kVA 9.7 10.4 15.6
Breaker Capacity A 40 50 60
Refrigerant R-407C
Chiller Compressor Output kW 3.75 2.2 × 2 3.0 × 2
Operating Noise Level (50/60 Hz)※1 dB(A) 60/64 62/66 64/67
  1. Operating noise level measured from a position of 1.5 m in front and at a height of 1 m.
  • Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
  • Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
  • Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
  • Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
  • Remote operation and stop signals can be controlled by momentary switches.
  • The RAX300F-E and RAX380F-E models have the following features: 2-level (50% and 100%) capacity-control method, max. 0.2 s auto-recovery after power outage, auto switch-over operation between compressors 1 and 2, separate alarm monitor, and 2 types of alarm signal terminals (for primary and supplementary alarms).
  • An air cooled model, RAX450F-E is available as a built -to-order item.
  • An alarm-equipped electric drain trap is available by special order.
  • Air inlet/outlet connection companion flanges are not included.
  • Flange: JIS10KFF equiv.
  • Models with secondary heat exchangers made with stainless steel piping are available. Please inquire for further information.
  • Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
  • RAX240F, RAX300F-E, RAX380F-E models are Class 2 Pressure Vessel targeted items.
  • Class 2 Pressure Vessel targeted models are built-to-order items.
RAX240F-W / RAX300F-WE / RAX380F-WE / RAX450F-WE
Model Water Cooled
Standard Energy Saving
RAX 240F-W 300F-WE 380F-WE 450F-WE
Air Processing Capacity (50/60 Hz) m3/min 42/49 51/60 64/75 83/98
Inlet Air Temp. Range / Outlet Air Dew Point 5 to 60 / Under pressure: 10
Working Fluid / Operable Ambient Temp. Range Compressed air / 2 to 45
Operating Pressure Range (Gauge pressure) MPa 0.29 to 0.98 0.29 to 0.93
Cooling Water Water Temp. 32
Water Flow Rate※1 m3/h 3.8 4.0 5.0 7.1
External Dimensions Height mm 1583 1650 1703
Depth mm 905 1100 1145
Width mm 1969 2020 2077
Mass kg 532 790 870 940
Auto
Drain
Trap
Model AD-5
Drain Release Port Size Rc1/2
Air Inlet/Outlet Connection Port Size 4B 100A flange 5B 125A flange 6B 150A flange
Cooling Water Inlet/Outlet Connection Port Size Female thread Rp1 Rc1 1/2
Electrical Specifications Voltage (50/60 Hz) V Three-phase 200/200,220
Power Consumption (50/60 Hz) kW 3.5/4.4,4.3 5.1/5.7,5.7 6.5/7.6,7.5 8.5/9.0,8.9
Electric Current (50/60 Hz) A 14.8/15.0,14.9 17.6/18.9,18.4 22.5/25.0,24.5 29.6/32.0,31.4
Power Supply Capacity kVA 8.3 8.7 11.4 15.6
Breaker Capacity A 30 50 60
Refrigerant R-407C
Chiller Compressor Output kW 3.75 2.2 × 2 3.0 × 2 3.75 × 2
Operating Noise Level (50/60 Hz)※2 dB(A) 52/55 57/58 55/58 55/62
  1. Cooling water flow rate is for 60 Hz.
  2. Operating noise level measured from a position of 1.5 m in front and at a height of 1 m.
  • Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
  • Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
  • Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
  • Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
  • Remote operation and stop signals can be controlled by momentary switches.
  • The RAX300F-WE, RAX380F-WE, and RAX450F-WE models have the following features: 2-level (50% and 100%) capacity-control method, max. 0.2 s auto-recovery after power outage, auto switch-over operation between compressors 1 and 2, separate alarm monitor, and 2 types of alarm signal terminals (for primary and supplementary alarms).
  • An alarm-equipped electric drain trap is available by special order.
  • Air inlet/outlet connection companion flanges are not included.
  • Flange: JIS10KFF equiv.
  • Models with secondary heat exchangers made with stainless steel piping are available. Please inquire for further information.
  • Please contact ORION regarding custom built models of specifications outside the ranges listed herein.
  • RAX240F-W, RAX300F-WE, RAX380F-WE, RAX450F-WE models are Class 2 Pressure Vessel targeted items.
  • Class 2 Pressure Vessel targeted models are built-to-order items.