Heavy Duty RAX-J Series Air Dryer Operation possible even in ambient temperatures of 48 °C. Uses a stainless steel shell heat exchanger.
Air Cooled
RAX75J~RAX190J /
RAX240F / RAX300F-E~RAX380F-E
Water Cooled
RAX75J-W~RAX190J-W /
RAX240F-W / RAX300F-WE~RAX450F-WE
Air Cooled
RAX75J~RAX190J /
RAX240F / RAX300F-E~RAX380F-E
RAX240F / RAX300F-E~RAX380F-E
Water Cooled
RAX75J-W~RAX190J-W /
RAX240F-W / RAX300F-WE~RAX450F-WE
RAX240F-W / RAX300F-WE~RAX450F-WE
- Air Processing Capacity
-
Air Cooled12.1/13.4 to 59/69 m3/minWater Cooled12.1/14 to 83/98 m3/min
- Intake Air Temperature
- 5 to 60 °C
- Compatible Air Compressor
-
Air Cooled75 to 380 kWWater Cooled75 to 450 kW
Features
Heavy Duty RAX-J Series Air Dryer Features
Stainless Steel Shell Heat Exchanger
Built with a stainless steel shell heat exchanger, the RAX is a perfect match for the age of clean, oil-free compressed air.
- Please inquire regarding drain oil processing.
- Stainless steel piping for improved corrosion-resistance is available by special order.
- RAX75J~190J-W models are not Class 2 Pressure Vessel targeted items.
This equipment does not fall under the Class 2 Pressure Vessel Safety Law and therefore is not subject to the required certification procedures etc.
- Multiple connected heat exchanger configuration available (by special order).
- RAX240F~450F-WE (Class 2 Pressure Vessel targeted items)
RAX75J~190J-W Features
The Air Dryer that Keeps Going!
Works in Ambient Temps. to 48 °C
Increased Air Processing Capacity
- Compared with previous 50 Hz, air cooled models.
Space Saving & Compact
Product Volume and Installation Space Reduced by 30% (Compared with previous models)
Can Be Closed-in on Left or Right Side
Drain Trap Installation
- Note that right-side installation requires optional parts.
- Right-side only on RAX150J(-W) and RAX190J(-W) models.
RAX240F~450F-WE Features
Saves energy by controlling the number of cooling compressors. (Energy saving type)
Automatic single refrigerant cycle operation (50%) or double refrigerant cycle operation (100%) based on processed air load. Up to 50% savings on electricity bill possible.
Operates with low loads below 0.01 MPa. (RAX240F / RAX240F-W)
Low pressure-loss (pressure-drop) heat exchanger sports little clogging even after long operating hours.
| 0.69MPa | 0.006~0.01MPa※ |
|---|---|
| 0.98 MPa (Max. operating pressure) | 0.004~0.008MPa※ |
- Noted flow rate values is for 50 Hz.
Easy Maintenance and Set-Up
(1) Exhaust duct may be installed above the dryer, saving precious floor space. (Air-cooled models)
(2) Design allows front access to main parts for maintenance and inspection.
- If space is limited, the right side of the dryer can be placed against a wall.
Specifications
RAX75J~RAX190J
| Model | Air Cooled | |||||||
|---|---|---|---|---|---|---|---|---|
| RAX | 75J | 90J | 120J | 150J | 190J | |||
| Air Processing Capacity (50/60 Hz) | m3/min | 12.1/13.4 | 17.3/20.1 | 22.1/25.3 | 27.5/32.0 | 34.1/40.5 | ||
| Inlet Air Temp. Range / Outlet Air Dew Point | ℃ | 5 to 60 / Under pressure: 10 | ||||||
| Working Fluid / Operable Ambient Temp. Range | ℃ | Compressed air / 2 to 48 | ||||||
| Operating Pressure Range (Gauge pressure) | MPa | 0.29 to 0.98 | ||||||
| External Dimensions | Height | mm | 1140 | 1286 | 1332 | |||
| Depth | mm | 1081 | 1244 | 1290 | ||||
| Width | mm | 470 | 700 | |||||
| Mass | kg | 146 | 186 | 205 | 279 | 286 | ||
| Auto Drain Trap |
Model | AD-5 | ||||||
| Drain Release Port Size | Rc1/2 | |||||||
| Air Inlet/Outlet Connection Port Size | R2 | 2 1/2B 65A flange | 3B 80A flange | |||||
| Electrical Specifications | Voltage (50/60 Hz) | V | Three-phase 200/200,220 | |||||
| Power Consumption (50/60 Hz) | kW | 2.5/3.0,3.0 | 3.0/3.9,3.9 | 4.1/5.2,5.2 | 5.7/7.5,7.4 | |||
| Electric Current (50/60 Hz) | A | 9.5/9.5,9.4 | 11.5/12.0,12.0 | 14.0/16.5,15.5 | 20.5/24.5,22.5 | |||
| Power Supply Capacity | kVA | 5.0 | 6.3 | 7.8 | 10.4 | |||
| Breaker Capacity | A | 20 | 30 | 40 | ||||
| Refrigerant | R-410A | |||||||
| Chiller Compressor Output | kW | 1.9 | 2.2 | 3.0 | 4.2 | |||
| Operating Noise Level (50/60 Hz)※1 | dB(A) | 67/70 | 70/73 | 71/74 | ||||
- Operating noise level measured from a position of 1 m in front and at a height of 1 m.
- Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
- Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
- Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
- Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
- Air inlet/outlet connection companion flanges are not included.
- Compatible flange: JIS10KFF equiv.
- RAX75J~RAX190J models include eye bolts (suspension bolts).
- Models with secondary heat exchangers made with stainless steel piping are available. Please inquire for further information.
- Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
RAX75J-W~RAX190J-W
| Model | Water Cooled | |||||||
|---|---|---|---|---|---|---|---|---|
| RAX | 75J-W | 90J-W | 120J-W | 150J-W | 190J-W | |||
| Air Processing Capacity (50/60 Hz) | m3/min | 12.1/14.0 | 17.3/20.1 | 22.1/25.3 | 27.5/32.0 | 35.0/41.0 | ||
| Inlet Air Temp. Range / Outlet Air Dew Point | ℃ | 5 to 60 / Under pressure: 10 | ||||||
| Working Fluid / Operable Ambient Temp. Range | ℃ | Compressed air / 2 to 48 | ||||||
| Operating Pressure Range (Gauge pressure) | MPa | 0.29 to 0.98 | ||||||
| Cooling Water | Water Temp. | ℃ | 32 | |||||
| Water Flow Rate※1 | m3/h | 1.7 | 2.8 | 2.9 | 3.0 | 3.2 | ||
| External Dimensions | Height | mm | 1140 | 1286 | 1332 | |||
| Depth | mm | 1081 | 1244 | 1290 | ||||
| Width | mm | 470 | 700 | |||||
| Mass | kg | 140 | 183 | 203 | 270 | 277 | ||
| Auto Drain Trap |
Model | AD-5 | ||||||
| Drain Release Port Size | Rc1/2 | |||||||
| Air Inlet/Outlet Connection Port Size | R2 | 2 1/2B 65A flange | 3B 80A flange | |||||
| Cooling Water Inlet/Outlet Connection Port Size | メスネジ | Rp3/4 | ||||||
| Electrical Specifications | Voltage (50/60 Hz) | V | Three-phase 200/200,220 | |||||
| Power Consumption (50/60 Hz) | kW | 1.7/2.0,2.0 | 2.1/2.6,2.5 | 3.5/4.2,4.2 | 4.7/6.2,6.1 | |||
| Electric Current (50/60 Hz) | A | 8.0/8.0,8.0 | 8.6/9.4,8.9 | 11.5/12.0,11.0 | 15.5/17.0,16.0 | |||
| Power Supply Capacity | kVA | 4.0 | 5.2 | 7.1 | 9.8 | |||
| Breaker Capacity | A | 15 | 20 | 30 | 40 | |||
| Refrigerant | R-410A | |||||||
| Chiller Compressor Output | kW | 1.9 | 2.2 | 3.0 | 4.2 | |||
| Operating Noise Level (50/60 Hz)※2 | dB(A) | 54/56 | 56/56 | 57/57 | 57/58 | |||
- Cooling water flow rate is for 60 Hz.
- Operating noise level measured from a position of 1.5 m in front and at a height of 1 m.
- Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
- Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
- Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
- Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
- Air inlet/outlet connection companion flanges are not included.
- Flange: JIS10KFF equiv.
- RAX75J-W~190J-Wはアイボルト(吊りボルト)付です。
- RAX75J-W~RAX190J-W models include eye bolts (suspension bolts).
- Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
RAX240F / RAX300F-E / RAX380F-E
| Model | Air Cooled | |||||
|---|---|---|---|---|---|---|
| Standard | Energy Saving | |||||
| RAX | 240F | 300F-E | 380F-E | |||
| Air Processing Capacity (50/60 Hz) | m3/min | 38/45 | 47/55 | 59/69 | ||
| Inlet Air Temp. Range / Outlet Air Dew Point | ℃ | 5 to 60 / Under pressure: 10 | ||||
| Working Fluid / Operable Ambient Temp. Range | ℃ | Compressed air / 2 to 40 | ||||
| Operating Pressure Range (Gauge pressure) | MPa | 0.29~0.98 | 0.29~0.93 | |||
| External Dimensions | Height | mm | 1583 | 1650 | ||
| Depth | mm | 905 | 1100 | |||
| Width | mm | 1969 | 2020 | |||
| Mass | kg | 555 | 790 | 870 | ||
| Auto Drain Trap |
Model | AD-5 | ||||
| Drain Release Port Size | Rc1/2 | |||||
| Air Inlet/Outlet Connection Port Size | 4B 100A flange | 5B 125A flange | ||||
| Electrical Specifications | Voltage (50/60 Hz) | V | Three-phase 200/200,220 | |||
| Power Consumption (50/60 Hz) | kW | 4.6/5.7,5.6 | 5.9/6.8,6.8 | 8.6/10.1,10.0 | ||
| Electric Current (50/60 Hz) | A | 17.9/19.2,19.1 | 19.9/22.3,21.2 | 26.4/29.4,28.9 | ||
| Power Supply Capacity | kVA | 9.7 | 10.4 | 15.6 | ||
| Breaker Capacity | A | 40 | 50 | 60 | ||
| Refrigerant | R-407C | |||||
| Chiller Compressor Output | kW | 3.75 | 2.2 × 2 | 3.0 × 2 | ||
| Operating Noise Level (50/60 Hz)※1 | dB(A) | 60/64 | 62/66 | 64/67 | ||
- Operating noise level measured from a position of 1.5 m in front and at a height of 1 m.
- Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
- Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
- Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
- Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
- Remote operation and stop signals can be controlled by momentary switches.
- The RAX300F-E and RAX380F-E models have the following features: 2-level (50% and 100%) capacity-control method, max. 0.2 s auto-recovery after power outage, auto switch-over operation between compressors 1 and 2, separate alarm monitor, and 2 types of alarm signal terminals (for primary and supplementary alarms).
- An air cooled model, RAX450F-E is available as a built -to-order item.
- An alarm-equipped electric drain trap is available by special order.
- Air inlet/outlet connection companion flanges are not included.
- Flange: JIS10KFF equiv.
- Models with secondary heat exchangers made with stainless steel piping are available. Please inquire for further information.
- Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
- RAX240F, RAX300F-E, RAX380F-E models are Class 2 Pressure Vessel targeted items.
- Class 2 Pressure Vessel targeted models are built-to-order items.
RAX240F-W / RAX300F-WE / RAX380F-WE / RAX450F-WE
| Model | Water Cooled | ||||||
|---|---|---|---|---|---|---|---|
| Standard | Energy Saving | ||||||
| RAX | 240F-W | 300F-WE | 380F-WE | 450F-WE | |||
| Air Processing Capacity (50/60 Hz) | m3/min | 42/49 | 51/60 | 64/75 | 83/98 | ||
| Inlet Air Temp. Range / Outlet Air Dew Point | ℃ | 5 to 60 / Under pressure: 10 | |||||
| Working Fluid / Operable Ambient Temp. Range | ℃ | Compressed air / 2 to 45 | |||||
| Operating Pressure Range (Gauge pressure) | MPa | 0.29 to 0.98 | 0.29 to 0.93 | ||||
| Cooling Water | Water Temp. | ℃ | 32 | ||||
| Water Flow Rate※1 | m3/h | 3.8 | 4.0 | 5.0 | 7.1 | ||
| External Dimensions | Height | mm | 1583 | 1650 | 1703 | ||
| Depth | mm | 905 | 1100 | 1145 | |||
| Width | mm | 1969 | 2020 | 2077 | |||
| Mass | kg | 532 | 790 | 870 | 940 | ||
| Auto Drain Trap |
Model | AD-5 | |||||
| Drain Release Port Size | Rc1/2 | ||||||
| Air Inlet/Outlet Connection Port Size | 4B 100A flange | 5B 125A flange | 6B 150A flange | ||||
| Cooling Water Inlet/Outlet Connection Port Size | Female thread | Rp1 | Rc1 1/2 | ||||
| Electrical Specifications | Voltage (50/60 Hz) | V | Three-phase 200/200,220 | ||||
| Power Consumption (50/60 Hz) | kW | 3.5/4.4,4.3 | 5.1/5.7,5.7 | 6.5/7.6,7.5 | 8.5/9.0,8.9 | ||
| Electric Current (50/60 Hz) | A | 14.8/15.0,14.9 | 17.6/18.9,18.4 | 22.5/25.0,24.5 | 29.6/32.0,31.4 | ||
| Power Supply Capacity | kVA | 8.3 | 8.7 | 11.4 | 15.6 | ||
| Breaker Capacity | A | 30 | 50 | 60 | |||
| Refrigerant | R-407C | ||||||
| Chiller Compressor Output | kW | 3.75 | 2.2 × 2 | 3.0 × 2 | 3.75 × 2 | ||
| Operating Noise Level (50/60 Hz)※2 | dB(A) | 52/55 | 57/58 | 55/58 | 55/62 | ||
- Cooling water flow rate is for 60 Hz.
- Operating noise level measured from a position of 1.5 m in front and at a height of 1 m.
- Conditions of air to be processed: Inlet pressure (gauge pressure): 0.69 MPa; Inlet air temp.: 40 °C; Outlet air dew point: –17 °C at atmospheric pressure, 10 °C under pressure; Ambient temp.: 32 °C.
- Please contact us for guaranteed performance specifications. Heavy duty models have had performance specifications confirmed with a test load (inspection under low pressure air).
- Air processing capacity is calculated based on air compressor intake conditions. (Atmospheric pressure, 32 °C, 75%)
- Standard equipped with remote control terminals (no-voltage), operation signal terminals (no-voltage), alarm signal terminals (no-voltage.)
- Remote operation and stop signals can be controlled by momentary switches.
- The RAX300F-WE, RAX380F-WE, and RAX450F-WE models have the following features: 2-level (50% and 100%) capacity-control method, max. 0.2 s auto-recovery after power outage, auto switch-over operation between compressors 1 and 2, separate alarm monitor, and 2 types of alarm signal terminals (for primary and supplementary alarms).
- An alarm-equipped electric drain trap is available by special order.
- Air inlet/outlet connection companion flanges are not included.
- Flange: JIS10KFF equiv.
- Models with secondary heat exchangers made with stainless steel piping are available. Please inquire for further information.
- Please contact ORION regarding custom built models of specifications outside the ranges listed herein.
- RAX240F-W, RAX300F-WE, RAX380F-WE, RAX450F-WE models are Class 2 Pressure Vessel targeted items.
- Class 2 Pressure Vessel targeted models are built-to-order items.