Drain TrapAutomatic Drain Release of Oil and Water

Drain Trap with Timer ADE4B
ADE-2-B / ADE-3-B Motor-Valve Drain Trap
FD2-G3 / FD2-NC-G3 / FD-5-G3 / FD6-G3 / FD-10-A Float Operated Drain Trap
AD-5-G1 Disc Operated Drain Trap

ADE300 Solenoid Operated Drain Trap
  • Equipped with capacitive liquid level sensor.
  • No clogging due to grime and foreign matter thanks to the wide mouth on the orifice of our solenoid valve.
  • Remote Operation Possible (Standard equipped with operation and alarm lines.)
ADE300
ADE300
*/ ?>
ADE-2-B / ADE-3-B Motor-Valve Drain Trap
  • Automatic Drain Release with Water Level Sensor
  • Adjustable timer controlled variable drain release interval (ADE-3-B)
ADE-3-B
ADE-3-B
FD2-G3 / FD2-NC-G3 / FD-5-G3 / FD6-G3 / FD-10-A Float Operated Drain Trap
  • Drains without air loss.
FD-5 / FD6
FD-5 / FD6
AD-5-G1 Disc Operated Drain Trap
  • Adjustable drain interval.
AD-5
AD-5

Specifications

Timer Operated
ADE4B
Max. Drain Release 0.32 L per cycle (at 0.69 MPa)
Drain Holding Capacity L -
Operating Pressure Range MPa 0.25 to 0.98
Operable Temperature Range 2 to 40 (Not freezing conditions)
Operating Fluid Compressed Air Drain
Drain Release Method Solenoid valve, timer and temperature-detection control method
Electrical Specifications Power Supply V(Hz) Single-phase 200 (50/60)
Power Consumption W 19/16
Connection Port Size Drain Inlet Port Rc1/2
Drain Outlet Rc1/2
Sludge Drain Port -
External Dimensions (HxDxW) mm 150×117×100
Mass kg 1.2
  • For indoor use. (Operable in environments where it would not be exposed to water splash.)
  • Includes manual drain release (test) button.
  • An anti-freeze heater is required to prevent drain from freezing in very cold climates. (Anti-freeze heater for commercial water lines.)
  • If drain piping is going to be aggregated, install check valves such that this unit does not receive pressure from other drain traps. Also, install one drain trap for each location.
  • Piping (inlet and outlet) for the ADE4B should have an inside diameter of at least 12 mm.
  • Please contact us for details.
Motor Valve Operation
ADE-2-B ADE-3-B
Performance Maximum Drain Capacity※1 Drain Water Only cm3/cycle 390
Air Only L/cycle 16
Drain Release Interval min 60 (fixed) 2, 5, 10, 20, 30 (adjustable)
Minimum Drain Release Time s 3.6 / 3.0
Operating Pressure Range (Gauge pressure) MPa 0.05 to 1.47 0.05 to 0.98
Operable Temperature Range 2 to 40
Operating Fluid Compressed air
Drain Release Method Motor valve timer, water level detection control
Electrical Specifications Power Supply V(Hz) Single-phase 200 (50/60)
Power Consumption W 5 or lower
Connection Port Size Inlet Includes 1/2, 3/8, 1/4 fittings to choose from. Rc1/2
Drain Outlet Port Φ10 hose nipple
Mass kg 1.0
External Dimensions (HxDxW) mm 105×126×170 105×126×175
Float Operated
FD2-G3/
FD2-NC-G3
FD-5-G3 FD6-G3 FD-10-A
Performance Maximum Drain Capacity※1 Drain Water Only cm3/cycle 10 10 30 80
Air Only L/cycle -
Drain Release Interval min -
Minimum Drain Release Time s -
Operating Pressure Range (Gauge pressure) MPa 0.1 to 1.0 / 0.15 to 1.0 0.05 to 0.98 0.1 to 1.0 0.20 to 0.98
Operable Temperature Range 2 to 60
Operating Fluid Compressed air
Drain Release Method Float Operated
Electrical Specifications Power Supply V(Hz) -
Power Consumption W -
Connection Port Size Inlet Rc1/2
Drain Outlet Port Hose nipple Rc1/4 Hose nipple Rc3/8
Mass kg 0.3 0.5 0.45 1.0
External Dimensions Refer to the External Diagram
Disc Operated
AD-5-G1
Performance Maximum Drain Capacity※1 Drain water only L/h 450
Air only L/cycle Approx. 0.3
Drain Release Interval min -
Minimum Drain Release Time s -
Operating Pressure Range (Gauge pressure) MPa 0.29 to 0.98
Operable Temperature Range 2 to 60
Operating Fluid Compressed air
Drain Release Method Disc operated
Electrical Specifications Power Supply V(Hz) -
Power Consumption W -
Connection Port Size Inlet Rc1/2
Drain Outlet Port Rc1/2
Mass kg 1.7
External Dimensions mm Refer to the External Diagram
  1. Drain capacity condition: air pressure (gauge pressure) of 0.69 MPa.
  2. Note that water detection might not be possible in cases where the drain water has low electrical conductivity, such as cases where an oil-free air compressor is used, etc.
  • The default setting for the adjustable timer is 20 min. (Motor valve type.)
  • NC (normally closed): If the inside of the trap is not pressurized, then the drain release valve will be closed.
  • Drain intake port (G3 piping connection port) can take piping from either above or from the side, and the unused port should be stopped by screwing in a plug.
  • Please contact us for details.
  • If connecting tubing to models FD2-G3 / FD2-NC-G3, or FD6-G3, use nylon tubing with an I.D. of Φ5.7 to Φ6.0 (O.D. Φ8).