Solenoid valve, timer and temperature-detection control method
Electrical Specifications
Power Supply
V(Hz)
Single-phase 200 (50/60)
Power Consumption
W
19/16
Connection Port Size
Drain Inlet Port
Rc1/2
Drain Outlet
Rc1/2
Sludge Drain Port
-
External Dimensions (HxDxW)
mm
150×117×100
Mass
kg
1.2
For indoor use. (Operable in environments where it would not be exposed to water splash.)
Includes manual drain release (test) button.
An anti-freeze heater is required to prevent drain from freezing in very cold climates. (Anti-freeze heater for commercial water lines.)
If drain piping is going to be aggregated, install check valves such that this unit does not receive pressure from other drain traps. Also, install one drain trap for each location.
Piping (inlet and outlet) for the ADE4B should have an inside diameter of at least 12 mm.
Drain capacity condition: air pressure (gauge pressure) of 0.69 MPa.
Note that water detection might not be possible in cases where the drain water has low electrical conductivity, such as cases where an oil-free air compressor is used, etc.
The default setting for the adjustable timer is 20 min. (Motor valve type.)
NC (normally closed): If the inside of the trap is not pressurized, then the drain release valve will be closed.
Drain intake port (G3 piping connection port) can take piping from either above or from the side, and the unused port should be stopped by screwing in a plug.
Please contact us for details.
If connecting tubing to models FD2-G3 / FD2-NC-G3, or FD6-G3, use nylon tubing with an I.D. of Φ5.7 to Φ6.0 (O.D. Φ8).