For when the air consumption momentarily surpasses the compressor discharge capacity.
For load balancing for systems employing 2 or more compressors.
For use before a heatless air dryer.
Specifications
MST
39A-100
95C-100
160C-100
230A-100
400D-100
600D-100
Volume
L
39
97
162
227
395
595
Common Pressure
MPa
0.98
Maximum Working Pressure
MPa
1.08
Maximum Inlet Air Temperature
℃
75
Connection Port Size (Inlet, Outlet)
1/2B
1B
1 1/2B
2 1/2B
Pressure Gauge
1/4B×50
1/4B×60
3/8B×75
Drain Valve
1/4B
1/2B
Safety Valve
1/4B
3/8B
1/2B
Air valve
1/2B
1B
-
Mass
kg
24
50
75
116
235
310
MST
800D-90
1000D-90
1200D-90
1500D-90
2000D-90
3000C-90
Volume
L
799
987
1200
1498
1980
3000
Common Pressure
MPa
0.88
Maximum Working Pressure
MPa
0.98
Maximum Inlet Air Temperature
℃
75
Connection Port Size (Inlet, Outlet)
2 1/2B
3B
Pressure Gauge
3/8B × 75
Drain Valve
1/2B
Safety Valve
1B
Air valve
-
Mass
kg
370
450
485
575
730
1155
Optional auto drain trap.
Please contact us for guaranteed performance specifications.
Models MST-1500D-90 and above have special shipping requirements (and additional shipping fees.)
Volumes up to 5000 L are possible as special order items.
Please contact ORION regarding custom built models with specifications outside the ranges listed herein.
The MST39A-100 is not a Class 2 Pressure Vessel targeted item.
The tank inner surface is uncoated. In cases where potential rust formation would not be acceptable, please order one of our stainless steel tank OAT Series models, or specify that the tank receive an inner-wall coating. (Special order item.)