Tester Equipped Turntable-Style Thermostatic Chamber Tester Equipped High-Functionality Thermostatic Chamber

EST-H

Temperature Control Range [Low Temperature]
–40 to +25 ℃ (80 ℃)
Temperature Control Range [High Temperature]
Room-temperature (RT) + 40 ℃ to RT + 80 ℃ (125 ℃)
Temperature Drop Time [Low Temperature]
60 min or less (25 ℃ to –40 ℃)
Temperature Rise Time [High Temperature]
60 min or less (25 ℃ to +80 ℃)
  • New Turntable Type Thermal Test Chamber with Improved Operability
    • The workpiece will attain the prescribed temperature at one revolution of the turntable inside the thermostatic chamber.
    • We can manufacture the product with the number of turntable levels and partitioning that best suits your needs.
  • Table Partition and Inspection Area can be Produced to Match your Test Pieces
  • Automated Temperature Testing Saves Manpower
    Improved Throughput along with Reducing Space Requirements

Dedicated Temperature-Exposure Model Lineup also Available See our Turntable Type Thermostatic Chamber page for details.

Turntable Type Thermostatic Chambers EST-H
EST-H

Specifications

Item Low Temperature Chamber High Temperature Chamber Low/High Multipurpose Use
Heating Control Method Heat Pump Balance Control
(Utilizes waste heat)
Heater Control Heater Control
Temperature Control Temperature Control Range –40 to +30 Room Temperature (RT) + 40 to RT + 80 (+125)※1 –40 to +80
Temperature Distribution ±3 (Near the no-load work carrier)
Temperature Rise / Fall Time min Within 60
(25℃ → -40℃)
Within 60
(25℃ → 80℃)
Within 60(25℃ → -40℃)
Within 60 (25 ℃ → 80 ℃: refrigeration compressor stopped)
Control Method PID control / Pt100Ω sensor
Cooling Capacity (50/60 Hz) kW 0.8/1.0 (when at –40 ℃) - 0.8/1.0 (when at –40 ℃)
Heating Power kW 1 (when at 0 ℃)※2 6.0 (heater capacity) 7.5 (heater capacity)※3
Electrical Specifications Power Supply Three-phase 200V±10% 50/60Hz
Maximum Operating Current A 21 22 42
Power Supply Capacity kVA 8 8 15
Circuit breaker A 30 30 60
Refrigerant R404A - R404A
Chiller Compressor Output kW 3.75 - 3.7
Compressed air MPa 0.4 to 0.7
Cooling Water Flow Rate m3/h 1.7 (when at 32 ℃) - 1.7 (when at 32 ℃)
Water Pressure MPa 0.1 to 0.5 - 0.1 to 0.5
Connection Port Rc1 - Rc1
Mass kg 1000 750 1000
External Dimensions(W×D×H) mm 1200(1400※4
×2250
×1900(1950※5
1200(1400※4
×1950
×1900(1950※5
1200(1400※4
×2250
×1900(1950※5
  1. Temperature Range: Specification for work at room-temperature (RT) + 40 ℃ to +125 ℃ is also possible.
  2. Designed calculated value.
  3. The heating capacity will be reduced when the refrigeration compressor is operating.
  4. Dimensions when the inspection mechanism is built in.
  5. Dimensions are of the table drive unit and upper section are installed.