Pre-Cooling Heat Exchanger
for Hydrogen Stations (Water Cooled)
Hydrogen Stations that are Essential for the Next Generation of Eco-Cars will Take Full Advantage of our No.1 Standing and Knowhow
PEC10000A-WL / PEC22000A-WL /
PEC40000A-WL
- Cooling Capacity
(50/60Hz) - 10 to 40kW
- Operable Liquid Temperature Range
- -40 to -20℃
- Brine Circulating Load
- : 40 to 200 L/min
(Determined from required specifications)
- Liquid Tank Capacity
- 30 to 300L
(Determined from required specifications)
- Compressed Hydrogen Fueling Technology Standard Compliant
JPEC-S0003 (2014)・(2016) Compliant - High Pressure Gas Safety Law
Compliant with the General High Pressure Gas Safety Bylaw - Water Protection and Noise Limiting One-Package Panel Design
(Sound level 65 dB or lower) - 70% Energy Savings (compared with constant-speed compressors)
Inverter control offers pre-cooling to –40 °C.
Features
Hydrogen Station System
The abundant product lineup offered by ORION can meet the varying requirements of hydrogen hydrogen station systems.
Specifications
PEC10000A-WL | PEC22000A-WL | PEC40000A-WL | |||
---|---|---|---|---|---|
Cooling Capacity | kW | 10 | 22 | 44 | |
Temp Setting Range | ℃ | -40 to -20 | |||
Brine | Operating Pressure | MPa | 0.65 | ||
Working Liquid | Low-Temperature Brine (FP-40, fluorine, etc.) | ||||
Circulating Volume | L/min | 40 to 200 (Determined from required specifications) | |||
Inlet/Outlet | Rc | JIS 10K Flange | |||
Liquid Tank Capacity | L | 30 to 300 (Determined from required specifications) | |||
Cooling Water | Operable Temperature Range | ℃ | 5 to 32 | ||
Max. Operating Pressure | MPa | 0.69 | |||
Inlet/Outlet | Rc | JIS 10K Flange | |||
Water Flow Rate | L/min | 100 | 200 | 300 | |
Electrical Specifications | Power Supply | V (Hz) | Three-phase 200 (50/60), 220 (60) | Three-phase 400 (50/60), 440 (60) | |
Power Supply Capacity | kVA | 32 | 65 | 75 | |
Refrigerant | R404A | ||||
Compressed Air | Air Pressure | MPa | 0.5 | ||
Atmospheric Pressure Dew Point (ADP) | ℃ | –50 (May substitute with nitrogen gas) | |||
Air Capacity (ANR) | L/min | 0.5 to 5 (Determined from required specifications) | |||
High Pressure Gas Safety Law | General High Pressure Gas Safety Bylaw Compliant Refrigeration Safety Bylaw and Refrigeration Safety Bylaw-Related Standards Compliant |
||||
Fluorocarbon Emission Reduction Law | Category 1 Specified Product |
- We also have made many achievements with other specifications (such as mobile, compact, heavy duty). Please ask us for details.
- Pre-cooling chillers are built-to-order items.
Pre-Cooling Heat Exchanger
THP40A-HEX Microchannel Heat Exchanger |
TH150A-HEX Shell and Coil Heat Exchanger |
||
---|---|---|---|
Cooling Capacity | kW | JPEC-S0003(2016) Compliant | |
Design Pressure | MPa | 99.9 | |
Design Temperature | ℃ | -45 to 50 | |
Material Used in Pressure Resistant Areas | SUS316L Stainless Steel (Ni content ≧ 28.5) | HRX19 Stainless Steel (Ni content ≧ 28.5) |
- Pre-cooling heat exchangers are built-to-order items.
- Custom designs will be drawn up to match specific needs.
System Peripheral Equipment
Inverter Chiller
Applications
- Hydrogen Production Facility
Cooling Water Supply for Compressor - Cooling Water Supply for Pre-Cooling Chiller
- The linked page also has information about the RKE3750B-V model. Thank you for your understanding.
Air Equipment
Applications
- Dry Air Supply for Pre-Cooling Chiller (Heatless Air Dryer)
- Compressed Air Purification (Filter)
- Pressure Maintenance (Air Tank)
Heatless Air Dryer | |||||
---|---|---|---|---|---|
QSQ035A | QSQ080B-E | QSQ120B-E | |||
Air Processing Capacity | Dew Point (PDP) | ℃ | -40 (ADP -58℃) | ||
Inlet Air Capacity (0.69 MPa) | m3/min | 0.297 | 0.68 | 1.02 | |
Outlet Air Capacity | m3/min | 0.247 | 0.56 | 0.85 | |
Regeneration Air Capacity | m3/min | 0.05 | 0.12 | 0.17 | |
Operating Range | Operating Pressure | MPa | 0.39 to 0.98 | ||
Ambient Temperature | ℃ | 2 to 40 | |||
Inlet Air Temperature and Humidity | ℃、% | 5 to 50 / Below saturation (No water droplets) | |||
External Dimensions | Height | mm | 810 | 680 | 930 |
Depth | mm | 260 | 430 | 430 | |
Width | mm | 113 | 163 | 163 | |
Mass | kg | 11 | 26.5 | 34 | |
Piping Connection Size | Rc3/8 | Rc3/4 | RC3/4 | ||
Voltage (50/60 Hz) | V | Single-phase 100/200/220/230 |
Model MST | Air Tank | |||||
---|---|---|---|---|---|---|
160C-100 | 230A-100 | 400D-100 | 600D-100 | |||
Volume | L | 162 | 227 | 395 | 595 | |
Operating Range | Operating Fluid | Compressed Air | ||||
Operating Pressure | MPa | up to 0.98 | ||||
Inlet Air Temperature | ℃ | up to 75 | ||||
External Dimensions | Height | mm | 1450 | 1531 | 1380 | 1900 |
Depth | mm | Chamber: Φ406 | Chamber: Φ470 | Chamber: Φ718 | Chamber: Φ718 | |
Mass | kg | 75 | 116 | 235 | 310 | |
Piping Connection Size | Rc1 | Rc1 | Rc1 1/2 | RC2 1/2 | ||
Drain Connection | With 1/4 valve | With 1/2 valve |
Filter | |||||
---|---|---|---|---|---|
MSF75B | MSF150B | MSF200B | |||
Inlet Air Capacity (0.69 MPa) | m3/min | 0.35 | 1.2 | 1.8 | |
Degree of Filtration / Oil Concentration | µm | 0.01µm/0.01 wt ppm | |||
Operating Range | Operating Fluid | Compressed Air | |||
Operating Pressure | MPa | 0.05 to 1.57 | |||
Ambient Temperature | ℃ | 2 to 60 | |||
Inlet Air Temperature | ℃ | 5 to 60 | |||
External Dimensions | Height | mm | 237 | 237 | 364 |
Depth | mm | 90 | 90 | 125 | |
Width | mm | 92 | 92 | 130 | |
Mass | kg | 1.0 | 1.0 | 2.5 | |
Piping Connection Size | Rc3/8 | Rc3/4 | RC3/4 | ||
Drain Connection | Rc1/4 |