Dual Channel Chiller
For Fiber Laser
(Air Cooled/ Water Cooled)
Individual Supply Circuits for the Oscillator and Optical System, Both in a Single Unit

RKS1500G-MV-2CH /
RKE2200B1-V(W)-2CH /
RKE3750B-V(W)-2CH /
RKE5500B-V(W)-2CH /
RKE7500B-VW-2CH /
RKE11000B-V(W)-2CH

Laser Oscillator Output
1 to 12 kW
Cooling Capacity
(50/60Hz)
3.9 to 42 kW
Operable Liquid Temperature Range
3 to 35 ℃ (Oscillator)
(Does not include some functionality)
25 to 40 ℃ (Optical System)
Temperature Precision
±0.1 ℃ (Oscillator)
±1 ℃ (Optical System)
  • Lineup Includes 5 Air-Cooled and 5 Water-Cooled Models
  • Two temperatures are simultaneously supplied from a single chiller. No need to set up two chillers.
  • Achieve up to 30% energy savings.
  • Comes standard equipped with startup heater and relief valve (*1),
    copperless specification for optical circuit (*2), and
    a complete offering of standard equipment as well as a wealth of available options.
  1. Optical system only. Available as an optional item for the oscillator circuit.
  2. SUS Circuit, Ion Exchange Resin, Electrical Conductivity Meter
Dual Channel Chiller for Fiber Laser
RKE11000B-V-2CH
Space Saving
1. Avoids the Trouble of Setting Up 2 Chillers
  • Oscillator and optical system cooling in one package.
    (Individual control of 2 tanks and 2 pumps.)
  • Only requires the maintenance space of a single unit.
2. Set up footprint reduced by as much as 30% compared to standard arrangements.
User Friendly
1. Easy and Reliable Water Management
  • Copperless Optical System Circuit (Deionized Water Spec.) Standard
    (SUS Circuit, Ion Exchange Resin, Electrical Conductivity Meter)
2. Meets the Demands of your Oscillator
  • Comes equipped with startup heater and relief valve.
    • The relief valve comes as standard equipment for the optical system only, and is available as an option for the oscillator side.
  • Many Options Available!
    Customize with options such as water filters and flow rate alarms, etc., to meet the demands of your oscillator and processing equipment.

Circuit Diagram

Circuit Diagram

Energy-Saving Specs. are Top Class in the Industry!

The inverter controlled compressor and fan are automatically controlled to run at the minimum operating speed for optimized refrigeration cycle operation. And we've made it easy to set the minimum pump speed. We have achieved Eco-Operation with 3 drive sources.

Energy-Saving Specs. are Top Class in the Industry!

Equipment Table

Model Compressor
Inverter
TESC
Built In
Optical System
Copperless Spec.
Optical System
Electrical Conductivity Meter
Optical System
Ion Exchange Resin
Startup Heater Incl. Casters
Air Cooled RKS1500G-MV-2CH    
RKE2200B1-V-2CH  
RKE3750B-V-2CH Optional Equipment
RKE5500B-V-2CH Optional Equipment
RKE11000B-V-2CH  
Water Cooled RKE2200B1-VW-2CH  
RKE37500B-VW-2CH Optional Equipment
RKE5500B-VW-2CH Optional Equipment
RKE7500B-VW-2CH Optional Equipment
RKE11000B-VW-2CH  

Air Cooled Model Specifications

Laser Oscillator Output kW 1 2 3 4 to 6 7 to 10
Chiller Model   RKS1500G-MV-2CH RKE2200B1-V-2CH RKE3750B-V-2CH RKE5500B-V-2CH RKE11000B-V-2CH
Performance Cooling Capacity※1 kW 3.9/4.3 7.7 11.2 19.3 36.2
Oscillator Circulating Water   Clean Water
Temperature Setting Range 5 to 35 3 to 35
Temperature Precision ±0.1 (During periods of stable load)
Operating Range MPa 0.10 to 0.50 0.15 to 0.50 0.08 to 0.50 0.25 to 0.80
Operating Flow Rate (0.5 MPa) ※2 L/min 12/21 28/43 15 to 50 60 to 95 100 to 230
Optical System Cooling Capacity kW 1 2
Circulating Water   Conditioned water (Control range when shipped from factory: 30 to 50 µS/cm)
Operable Temperature setting 25 to 40 (Oscillator water temp setting + 5 ℃ or higher)
Temperature Precision ±1 (During periods of stable load)
Operating Range MPa 0.10 to 0.50
Operating Flow Rate (0.5 MPa)※3 L/min 24/52
Electrical Specifications Power Supply V(Hz) Three-phase 200 (50/60)
Power Consumption※1 kW 2.6/3.2 5.5/6.0 6.3/6.7 10.7/11.1 17.1/17.5
Electric Current※1 A 12.6/13.2 22/23 22.5/22.5 36.1/36.1 53/53
Power Supply Capacity kVA 6.0 8.7 9.2 13.2 21.7
Equipment Specifications Refrigeration Compressor kW 1.8 1.7 3.0 7.46
Condenser   Fin and Tube Forced Air Cooling
Oscillator Evaporator Construction   Plate type
Material   SUS316 (Cu brazing)
Optical System Evaporator Construction   Shell and Coil
Material   SUS304, plastic
Oscillator Discharge
Pump
Construction   Cascade Multistage centrifugal immersion type (SUS construction)
Output kW 0.4 0.75 1.1
(Inverter)
2.0
(Inverter)
2.5
(Inverter)
Optical System Discharge
Pump
Construction   Multistage centrifugal immersion type (SUS construction)
Output kW 0.65/1.05
Oscillator Heater kW 2.0 3.0 5.0
Optical System Heater kW 1.0
ファン出力 kW 0.025×2 0.11/0.14 0.4
(Inverter)
0.75
(Inverter)
0.4×2
(Inverter)
Oscillator Water Tank Capacity L Approx. 20 Approx. 20 Approx. 60 Approx. 90 Approx. 100
Optical System Water Tank Capacity L Approx. 10
Refrigerant   R410A
External Dimensions
H
×
L
×
W
mm 1140
×
700
×
627
1080
×
1200
×
660
1410
×
752
×
950
1700
×
854
×
1100
1700
×
854
×
1610
  1. When operating under the following conditions: ambient temperature: 32 ℃ (1500 model: 25 ℃); water temperature: 20 ℃. Cooling capacity is the combined power of the oscillator and optical circuit, and is at least 95% of the noted power.
  2. The optical system cooling water flow rate will be 0 to 10 L/min, and therefore the actual flow rate for the oscillator system delivered outside the product will be reduced by 0 to 10 L/min.
  3. The flow rate through the ion exchange resin will be 0 to 2 L/min, and therefore the flow rate for the optical system outside the product will be reduced by 0 to 2 L/min.
  • Specifications may be improved without notice.
  • External dimensions are for reference.

Water Cooled Model Specifications

Laser Oscillator Output kW 1 to 2 3 4 to 6 7 to 8 10 to 12
Chiller Model RKE 2200B1-VW-2CH 3750B-VW-2CH 5500B-VW-2CH 7500B-VW-2CH 11000B-VW-2CH
Performance Cooling Capacity※1 kW 9.4 13.1 22.4 26.3 42.0
Oscillator Circulating Water   Clean Water
Temperature Setting Range 5 to 35 3 to 35
Temperature Precision ±0.1 (During periods of stable load)
Operating Range MPa 0.15 to 0.50 0.08 to 0.50 0.25 to 0.80
Operating Flow Rate (0.5 MPa)※2 L/min 28/43 15 to 50 60 to 95 100 to 230
Optical System Cooling Capacity kW 1 2
Circulating Water   Conditioned water (Control range when shipped from factory: 30 to 50 µS/cm)
Operable Temperature setting 25 to 40 (Oscillator water temp setting + 5 ℃ or higher)
Temperature Precision ±1 (During periods of stable load)
Operating Range MPa 0.10 to 0.50
Operating Flow Rate (0.5 MPa)※3 L/min 24/52
Electrical Specifications Power Supply V(Hz) Three-phase 200 (50/60)
Power Consumption※1 kW 4.4/5.0 6.0/6.4 9.7/10.1 11.0/11.4 15.4/15.8
Electric Current※1 A 20.0/20.0 25.2/25.2 37.8/37.8 39.0/39.0 47.0/47.0
Power Supply Capacity kVA 7.7 10.2 14.4 14.8 19.7
Equipment Specifications Refrigeration Compressor kW 1.7 3.0 4.6 7.46
Condenser   Double-pipe water cooling
Oscillator Evaporator Construction   Plate type
Material   SUS316 (Cu brazing)
Optical System Evaporator Construction   Shell and Coil
Material   SUS304, plastic
Oscillator Discharge
Pump
Construction   Cascade Multistage centrifugal immersion type (SUS construction)
Output kW 0.75 1.1
(Inverter)
2.0
(Inverter)
2.5
(Inverter)
Optical System Discharge
Pump
Construction   Multistage centrifugal immersion type (SUS construction)
Output kW 0.65/1.05
Oscillator Heater kW 2.0 3.0 5.0
Optical System Heater kW 1.0
Cooling Water Flow Rate※4 m3/h 1.8 2.4 3.4 3.5 4.2
Oscillator Water Tank Capacity L Approx. 20 Approx. 60 Approx. 90 Approx. 90 Approx. 100
Optical System Water Tank Capacity L Approx. 10
Refrigerant   R410A
External Dimensions
H
×
L
×
W
mm 1080
×
1200
×
660
1410
×
752
×
950
1700
×
854
×
1100
1700
×
854
×
1100
1410
×
854
×
1610
  1. When operating under the following conditions: cooling water temperature: 32 ℃; water temperature: 20 ℃. Cooling capacity is the combined power of the oscillator and optical circuit, and is at least 95% of the noted power.
  2. The optical system cooling water flow rate will be 0 to 10 L/min, and therefore the actual flow rate for the oscillator system delivered outside the product will be reduced by 0 to 10 L/min.
  3. The flow rate through the ion exchange resin will be 0 to 2 L/min, and therefore the flow rate for the optical system outside the product will be reduced by 0 to 2 L/min.
  4. When the chilled water temperature is 35 ℃, and the cooling water temperature is 32 ℃.
  • Specifications may be improved without notice.
  • External dimensions are for reference.