Operating Environment |
Nybrine (Z-1) 30 to 40% Solution※3 |
|
|
30 to 40% ethylene glycol solution ※3 |
|
Deionized (Conditioned) Water, Electrical Conductivity: 1 µS/cm or Higher |
Copperless Spec. Wetted Parts ※4 |
|
Working Liquid (Chilled Water) Temp |
5 to 35 ℃ |
|
|
0 to 35 ℃ |
|
|
Freeze-Prevention Mode |
This function operates the discharge pump in order to prevent drops in water temperature and freezing during winter months when the product is not otherwise operating. When enabled, the discharge pump will operate when the water temperature falls to 3 ℃ or below. |
|
|
Warm Up Mode |
This function will automatically operate the discharge pump at times when the product is otherwise not operating when the ambient temperature is low, for example during winter months, in order to prevent the water temperature from dropping too much and in order to help maintain the set water temperature. When this mode is enabled, the water temperature can be set within the temperature range of 10 to 35 ℃ as desired. |
|
|
Low Noise Mode |
This function will limit the upper speed of the fan, thus reducing the fan ventilation noise. ※4 |
|
|
Cleanroom (Leakage Alarm Spec.) |
In addition to the standard specification, leak-detect spec. models include leak-detection functionality (leakage sensor and leakage detection unit) built in. Pressure resistant piping, insulated refrigeration, piping, insulated water piping standard. (For models specified with leak detection specifications.) |
|
|
Water Leakage Detection |
The standard specification includes leak-detection functionality (leakage sensor and leakage detection unit) built in. |
|
|
Vibration Reducing Base |
Reduces transmission of vibration from the chiller. |
|
|
Chilled Water Circuit |
Discharge Pump Specs. ※1 |
High-Head Pump [A] |
|
|
|
|
|
High-Head Pump [B] |
|
|
Relief Valve (Pressure Valve) |
Can provide equipment-side pressure protection. |
|
|
Water Tank Water-Level Alarm (Lower limit alarm) |
Used to avoid water shortages due to evaporation. |
|
|
Automatic Water Supply |
A ball tap is provided in the water tank in order to maintain a uniform water level. |
|
|
Shipped with ball tap pre-installed. |
|
|
Chilled Water Inlet/Outlet Open/Close |
Gate valves are added to the chilled water inlet and outlet ports. |
|
|
A solenoid valve will be added to the chilled water inlet and outlet ports. |
|
|
Compression fittings are added to the chilled water inlet and outlet ports. |
|
|
Chilled Water Circuit Water Filter |
Water Filter A Assembly |
Filtration Degree: 5µm |
|
Water Filter A Assembly |
Filtration Degree: 10µm |
|
Water Filter A Assembly |
Filtration Degree: 20µm |
|
Water Filter A Assembly |
Filtration Degree: 50µm |
|
Water Filter A Assembly |
Filtration Degree: 100µm |
|
Deionizer for Chilled Water Circulation Circuit |
Deionizer F Assembly |
Water Quality: 10µS/cm or lower |
|
|
|
|
Deionizer H Assembly |
|
Deionizer G Assembly |
|
|
|
|
Deionizer for Chilled Water Circulation Circuit |
Deionizer Assembly for Supply Water |
|
|
Cooling Water (Condenser Circuit) Inlet/Outlet Open/Close ※ Model names ending with "W" are targeted for water cooled chillers. |
Gate valves are added to the cooling water inlet and outlet ports. |
|
|
|
Cooling water inlet and outlet ports have solenoid valves added. |
|
|
|
Compression fittings are added to the cooling water inlet and outlet ports. |
|
|
|
Bypass Circuit |
The bypass circuit is operated by manually opening and closing the cooling water circuit valves. |
|
(Built-In) |
Power Supply and Control |
Primary Power Supply Voltage |
Three-phase 200 V (50/60 Hz), three-phase 220 V (60 Hz) |
|
|
Three-phase 230 V (50 Hz), 380/400/415/440/480 V (50/60 Hz) |
|
|
Overload Safety Devices |
Built-in overload safety device. |
|
|
|
|
|
Power Outage Recovery Operation Setting |
Selects the product recovery pattern after a power outage. Manual recovery / Automatic recovery / Remote operation priority |
|
|
Operation Action Settings |
Can choose between "Local" and "Remote" operation. |
|
|
Alarm Signal Output Options |
Can choose the contact state of the remote alarm signal output. (Relay contacts either OPEN or CLOSED during an alarm condition.) |
|
|
Audible Alarm Enable/Disable |
Audible alarm for alarm/warning conditions enabled/disabled option. |
|
|
Liquid (Chilled Water) Temp Upper/Lower Limit Warning Option |
The method of abnormal liquid (chilled water) temperature detection can be selected. Can enable or disable the alarm and standby sequence for relative value and absolute value alarms. ※ Regarding the standby sequence, the alarm will be output after startup until the liquid temperature has initially reached a normal value and then later goes outside the normal range. |
|
|
Liquid (Chilled Water) Temp Upper/Lower Limit Warning / Absolute Value Upper Limit |
The warning will occur if the liquid temperature goes above the set temperature (2 to 40 ℃) regardless of the actual set water temperature. Will be enabled when the absolute values for "Liquid (Chilled Water) Temp Upper/Lower Limit Warning" have been selected. |
|
|
Liquid (Chilled Water) Temp Upper/Lower Limit Warning / Absolute Value Lower Limit |
The warning will occur if the liquid temperature goes below the set water temperature regardless of the actual set water temperature. Will be enabled when the absolute values for "Liquid (Chilled Water) Temp Upper/Lower Limit Warning" have been selected. |
|
|
Remote Control |
By connecting a remote control to the product, the product can be run and other operations can be conducted (limited control) from a control panel in a remote location. Operating parameters can also be displayed. |
Remote Control Set C |
|
Max. cable length: 20 m |
|
Max. cable length: 50 m |
|
Max. cable length: 100 m |
|
Communications Functions |
Communications Interface and Software |
|
|
Communications Device Address |
Enables communications functions and selects the address number of the unit when multiple units are connected together. The address no. can be arbitrarily set from 0 to 31. |
|
|
Settings Lock |
Locks and prevents changes to the water temperature setting and other parameter settings. |
|
|
Temperature Warning Signal Output Option |
Determines the open/closed state of contacts when a temperature warning signal is present. |
|
|
External Signal Operation |
Operation signal terminals |
No-Voltage Contacts |
|
Voltage output (200 V output) |
|
Alarm Signal Contacts |
No-Voltage Contacts |
|
Voltage output (200 V output) |
|
Remote Operation (No-voltage contacts) |
Max. cable length: 20 m |
|
Max. cable length: 100 m |
|
Remote Operation (24 Vdc Output) |
Max. cable length: 20 m
|
|
Max. cable length: 100 m
|
|
Remote Operation (200 Vac Input) |
Max. cable length: 20 to 100 m
|
|
Other |
CE Marking |
CE Compliant Models |
|
|
Casters |
With stopper |
|
|
|
(G2) |
|
|
External Surface Coating and Thickness |
Powder Coating: 30µm |
|
|
Salt Corrosion Prevention Spec. (Acrylic resin coating of at least 45 µm thick.) |
|
|
Color Designation
(Specified Munsell No. or JPMA (Japan Paint Manufacturers Association) No.
|
Melamine resin coating of at least 15 µm. |
|
|
For other paint/coatings |
|
|
|
Case by Case |
Packaging for Export |
Basic Plywood Packaging |
|
|
Water Temperature Control Precision |
±0.1℃ |
|
|
|
|
|
Heating Function |
Used to raise the temperature during product startup. (Built-in 200 Vac electric heater.)
ON/OFF control to the set fluid temperature minus 2 ℃ ± 0.5℃.
|
|
(Ext. dimensions modified)
|
Low-Load Response |
When high-precision control is required at loads below the minimum required amount. |
Optional Heater Control |
|
CCV Circuit Added |
|
|
|
|
Inspection Manual |
Japanese |
|
|
English |
|
|
Test Results Chart |
Japanese |
|
|
English |
|
|
Witnessed Inspection |
|
|
|
Replaceable Dust-Proof Filter |
|
On-Site OP |
|
|