Cooling Water Circulation Equipment [For Device Cooling]
RKS JM Series Mid-Grade Model, Compact Chiller with Built-In Water Tank
RKS J Series Economy Model, Compact Chiller with Built-In Water Tank
High precision temperature control offers improved processing precision and quality.
Comes standard with built-in high pressure pump.
Typical Applications: Laboratory Concentrator, Analysis Equipment, ICP Analysis Equipment, X-Ray Inspection Equipment
RKS-J Series Product Report
RKS-JM Series Product Report
Catalog Download


Product Outline
Specifications / Price
RKS JM Series Mid-Grade Model, Compact Chiller with Built-In Water Tank
Model | RKS401/402J-MV | RKS752/753J-MV | RKS1502/1503J-MV |
---|---|---|---|
Cooling Capacity | 1.3/1.5kW | 2.2/2.5kW | 4.9/5.3kW |
Operable Ambient Temperature | 5~45℃ | ||
Operable Temperature Range (Liquid temp) | 5~40℃ | ||
Temperature Control Precision | ±0.1℃ | ||
Standard Price (plus tax) | ¥396,000 | ¥472,000 | ¥656,000 |
Cooling Capacity | 1.3/1.5kW |
---|---|
Operable Ambient Temperature | 5~45℃ |
Operabl Temperature Range (Liquid temp) | 5~40℃ |
Temperature Control Precision | ±0.1℃ |
Standard Price (plus tax) | ¥396,000 |
Cooling Capacity | 2.2/2.5kW |
---|---|
Operable Ambient Temperature | 5~45℃ |
Operabl Temperature Range (Liquid temp) | 5~40℃ |
Temperature Control Precision | ±0.1℃ |
Standard Price (plus tax) | ¥472,000 |
Cooling Capacity | 4.9/5.3kW |
---|---|
Operable Ambient Temperature | 5~45℃ |
Operabl Temperature Range (Liquid temp) | 5~40℃ |
Temperature Control Precision | ±0.1℃ |
Standard Price (plus tax) | ¥656,000 |
RKS J Series Economy Model, Compact Chiller with Built-In Water Tank
Model | RKS753J-V | RKS1503J-V |
---|---|---|
Cooling Capacity | 2.2/2.5kW | 4.9/5.3kW |
Operable Ambient Temperature | 10~40℃ | |
Operabl Temperature Range (Liquid temp) | 15~35℃ | |
Temperature Control Precision | ±2.0℃ | |
Standard Price (plus tax) | ¥417,000 | ¥580,000 |
Cooling Capacity | 2.2/2.5kW |
---|---|
Operable Ambient Temperature | 10~40℃ |
Operabl Temperature Range (Liquid temp) | 15~35℃ |
Temperature Control Precision | ±2.0℃ |
Standard Price (plus tax) | ¥417,000 |
Cooling Capacity | 4.9/5.3kW |
---|---|
Operable Ambient Temperature | 10~40℃ |
Operabl Temperature Range (Liquid temp) | 15~35℃ |
Temperature Control Precision | ±2.0℃ |
Standard Price (plus tax) | ¥580,000 |
Features
Point 01: First in Class Performance with a Compact Body
RKS JM Series Mid-Grade Model, Compact Chiller with Built-In Water Tank
High Precision Temperature Control + Inverter Driven High Pressure Pump + High Temperature Environment Capability
- High precision temperature control of ±0.1 ℃ for improved processing precision and quality.
- Our standard built-in high-pressure pump is inverter driven, thus achieving the same performance in any region.
- The wide ranging operable ambient temperature range of 5 to 45 ℃ and operable liquid temperature range of 5 to 40 ℃ allow it to be used anywhere.
RKS J Series Economy Model, Compact Chiller with Built-In Water Tank
Easy to Use + Simple + Affordable
- Temperature control of ±2.0 ℃ is possible with compressor ON/OFF control.
- High Pressure Pump Built In
Point 02: We Offer Functionality Supporting Many Applications!
Choose from the many accessories available to meet your specific needs.

Bypass Piping Kit
Chilled water flow and pressure controllers are indispensable.

Automatic Water Supply Kit
Ball tap installed inside the tank.
Trouble-saving water-supply kit.

Relief Valve Kit
Indispensable when you don't want the chilled water circuit pressure to be higher than necessary.

Flow Gauge
Can be used to monitor the chilled water circuit flow rate.

Water Filter Housing
Removes foreign material from the chilled water circuit.
Choice of Element Possible (Sold separately)

Water Startup-Heater Kit
Separate standing startup heater.
Can also be used for control purposes.

Remote Communications Interface
Our Expansion Interface Board allows use of several accessories.

Drain Pan (SUS) Kit
Prevents damage in case of incidental water leaks.
The chiller is placed in the drain pan and secured in place.

Electrical Conductivity Meter
Allows for purity management of circulating water.
(Photo shows Addition of Bypass Circuit)
Application Examples
Suitable in Many Applications
Concentration Apparatus
Evaporator Cooling

Analysis Equipment
Analysis Stage Cooling

ICP Analysis Equipment
Cooling of Test Solutions, Etc.

X-Ray Inspection Equipment
Light Source and LED Chip Cooling

Specifications
Model | RKS753J-V | RKS1503J-V | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
401J-MV | 402J-MV | 752J-MV | 753J-MV | 1502J-MV | 1503J-MV | 753J-V | 1503J-V | ||||
Performance | Cooling Capacity(50/60Hz)※1 | kW | 1.3/1.5 | 2.2/2.5 | 4.9/5.3 | 2.2/2.5< | 4.9/5.3 | ||||
Heating Capacity※1 | kW | 0.53/0.53 | 0.6/0.6 | 1.1/1.1 | - | - | |||||
Operable Ambient Temperature Range | ℃ | 5~45 | 10~40 | ||||||||
Operating Liquid Temperature Range | ℃ | 5~40 | 15~35 | ||||||||
Operable Water Pressure | MPa | 0.05~0.2/0.3 | 0.1~0.6 | 0.05~0.2/0.3 (50/60Hz) |
0.1~0.5 | ||||||
Control Precision※4 | ℃ | ±0.1 | ±2.0 | ||||||||
Minimum Operable Circulation Rate(50/60Hz) | L/min | 10 (Head: 30 m) | 18 (Head: 60 m) | 10 (Head: 20/30 m) | 12/21 (Head: 50m) | ||||||
Electrical Specifications | Power Supply※2 | V(Hz) | Single-Phase 100 (50/60) |
Single-Phase 200〜300(50/60) | Three-Phase 200(50/60)・ 220(60) |
Single-Phase 200〜230(50/60) | Three-Phase 200(50/60)・220(60) | Three-Phase 200(50/60)・220(60) | |||
Power Consumption(50/60Hz)※1 | kW | 0.8/0.7 | 0.9/1.0 | 1.1/1.2 | 0.9/1.0 | 2.0/2.5 | 1.8/2.2 | 0.9/1.1 | 1.8/2.2 | ||
Current(50/60Hz)※1 | A | 7.9/7.3 | 3.8/4.7 | 5.2/5.4 | 3.6/3.4 | 7.6/8.5 | 6.6/8.2 | 4.1/4.1 | 6.8/7.4 | ||
Power Supply Capacity※3 | kVA | 1.2 | 1.5 | 2.0 | 2.0 | 4.2 | 4.2 | 2.0 | 4.2 | ||
Breaker Capacity※5 | A | 15 | 10 | 15 | 10 | 30 | 15 | 10 | 15 | ||
Operation Control Method | Electronic expansion valve capacity control | Compressor ON/OFF Control | |||||||||
Equipment Specifications | Refrigeration Compressor | kW | Hermetically sealed rotary type | ||||||||
0.55 | 0.6 | 0.75 | 0.85 | 1.2 | 1.8 | 0.85 | 1.8 | ||||
Condenser | Corrugated fin and tube parallel flow | ||||||||||
Evaporator | Construction | Plate type heat exchanger | |||||||||
Materials | SUS316(Brazing: Cu) | ||||||||||
Discharge Pump | Construction | Cascade type | |||||||||
Output | kW | 0.25(Inverter drive) | 0.4(Inverter drive) | 0.25 | 0.4 | ||||||
Water Tank Capacity | L | Approx.17 | |||||||||
Refrigerant | R-410A | ||||||||||
External Dimensions (H×D×W) | mm | 615×500×375 | 933×590×375 | 615×500×375 | 933×590×375 | ||||||
Product Mass (Dry weight) | kg | 42 | 45 | 46 | 72 | 68 | 45 | 67 | |||
Operating Noise (50/60Hz)※6 | dB | 59/62 | 59/60 | 61/62 | 62/63 | 64/65 | 65/66 | 61/63 | 63/66 | ||
Standard Price ※7 | ¥396,000 | ¥472,000 | ¥656,000 | ¥417,000 | ¥580,000 |
- Under the following conditions: Chilled water temp: 20 °C, ambient temp: 25 °C, at the maximum discharge pump circulating load. Cooling capacity is at least 95% of the noted figures. Heating capacity will change according to operating conditions.
- Source voltage phase unbalance should be less than ±3%.
- The figure noted is when operating at the highest capacity in the normal operating range.
- When the current load is continuously within ±10% and the ambient temperature is stable. However, this does not include starting times or when the heat-load exceeds the chiller capacity.
- Comes standard with a built-in overload protection circuit breaker (NFB).
- Operating noise levels are from a position of 1 m in front of the product and at a height of 1 m.
- The above prices do not include consumption tax.
- Note 1: The liquids (for chilled water) that can be used with this product are clean water or a 30 to 40% solution of industrial-use ethylene glycol. Alternatively, if conditioned water is used, then it should have an electrical conductivity of at least 1 μS/cm.
- Note 2: Heat output from the product (in kW) is approx. 1.3 times that of the cooling capacity.
- Note 3: Depending on the operating environment, situations such as condensation forming on piping inside the product or short-term leakage of leakage from the mechanical seals of the pump may occur. Please install a drain pan as needed in such cases.